A two-dimensional motion mixer, also known as a rock motion mixer, is a device that achieves material mixing through horizontal and vertical motion. Its core components include a drum, a swing frame, and a machine frame. Through the rotation of the drum and the swing of the swing frame, the material is fully rolled, diffused, and sheared in the mixing container, thereby achieving fast and uniform mixing.
The common faults and solutions of two-dimensional motion mixer mainly include the following:
1. The device cannot start:
Fault description:After pressing the start button, there is no response and an abnormal error code is displayed on the control panel.
Solution:
Check power supply: Ensure good contact of the power line, reconnect the power line and ensure good power supply.
Check the control system: Check if the sensor is faulty, replace the faulty sensor if necessary, and perform calibration and testing.
Cleaning and lubrication: Clean and lubricate the equipment, remove dust and dirt, inspect and adjust the transmission system.
2. Uneven mixing:
Reason for malfunction:It may be due to an unreasonable internal structure of the mixer or incorrect placement of materials.
Solution:Check the internal structure of the mixer to ensure that the materials are placed correctly, and adjust the speed or shape of the mixer if necessary.
3. Equipment leakage:
Reason for malfunction:The sealing strip is not tightly attached around the discharge door, resulting in material leakage.
Solution:Ensure that the sealing strip is tightly attached around the discharge door, and adjust the cylinder pressure or replace the seal if necessary.
4. Equipment vibration:
Reason for malfunction:Equipment imbalance or loose support feet.
Solution:Adjust the balance state of the equipment and tighten the support feet.
5. Bearing overheating:
Reason for malfunction:The bearing seat is uneven or the lubricating oil is improper.
Solution:Ensure that the bearing seat is level, add lubricating oil in a timely and quantitative manner, and maintain the lubricating oil level at 70% -80% of the bearing space.
6. Equipment temperature too high:
Reason for malfunction:Poor heat dissipation or abnormal material reaction.
Solution:Increase the cooling and ventilation of the equipment, pause stirring to handle abnormal materials.