2025 Pharmaceutical Science Popularization | Maintenance and Care Guide for Pen Insulin Syringes
Date: 2025-12-03Read: 5
  Pen insulin injector(referred to as "insulin pen" for short) is the core tool of daily insulin administration for diabetes patientsAccurate dose control, convenient operation, and excellent concealmentThe advantages have significantly improved patients' medication adherence and quality of life. However, the precise structure of insulin pens (involving mechanical transmission, dose display, needle connection, etc.), if not maintained properly (such as inadequate cleaning, component aging, improper storage), may lead toInaccurate dosage, leakage, and increased risk of infectionIt directly affects the effectiveness of blood glucose control and even triggers hypoglycemic/hyperglycemic events. This article will revolve aroundDaily cleaning, component inspection, storage standards, regular maintenance, and troubleshootingFive major links, providing systematic maintenance guidelines to assist patients and medical staff in ensuring the long-term stable operation of insulin pens.
1、 Understand the core structure and maintenance focus of insulin pens
The core structure of insulin pens includes:Pen core (including insulin solution), dosage adjustment knob, push rod (pushing piston injection), pen cap (protecting pen core and needle), dosage display window(Some models include memory function). The key to maintenance is to ensure:
  Accurate dosageThe push rod and knob are not stuck, and the display window reading is clear;
  leak-proof sealingThe connection between the pen core, push rod, and needle is not loose or aged;
  Aseptic safetyThe needle is disposable and the pen body is not contaminated;
  environmental adaptationAvoid temperature, humidity, or light during storage and use.
2、 Daily cleaning: avoid pollution, maintain hygiene status
Daily cleaning of insulin pens should follow“Gentle, non corrosive, and residue free”The principle is to clean the external and accessible parts of the pen body to avoid liquid infiltration into the internal precision structure.
  1. Cleaning frequency and timing​
  After each needle changeWipe the connection between the pen body and the needle with a dry cotton swab (to avoid blood or drug residue);
  After daily useUse a soft cloth dipped in warm water (≤ 40 ℃) to wipe the outside of the pen body (such as the pen holder and dosage knob) to remove fingerprints and liquid stains;
  Weekly deep cleaningIf the pen body is visibly dirty (such as food residue or sweat), the cleaning frequency can be increased.
  2. Cleaning methods and taboos​
  correct operation:
useNeutral soapy waterWet a soft cloth (such as eyeglass cloth or medical gauze) with a pH of 5.5~7.5, gently wipe the pen body, and avoid rubbing the dose display window with force (to prevent scratching);
Use after cleaningDry soft clothWipe dry to ensure there is no residual moisture (moisture can easily cause rusting of internal metal parts or short circuits in electronic components);
The inside of the pen cap (the part in contact with the needle) can be lightly wiped and disinfected with an alcohol swab (75% medical grade alcohol) (wait for the alcohol to evaporate before reinstalling the pen body).
  Absolute taboo:
Do not immerse the entire pen in water or rinse it (liquid infiltration can cause gear rust and circuit damage);
Do not use strong acid/alkali cleaning agents (such as bleach, toilet cleaner), and direct alcohol spraying (which may corrode plastic parts or rubber seals);
Avoid scratching the pen body with a hard bristled brush or nail (which may damage the surface coating or dosage scale).
3、 Component inspection and replacement: Regular physical examination of key components to prevent problems before they occur
The accuracy of insulin pens depends on the integrity of each component, and it is necessary to regularly inspect the following key components and replace aging or damaged parts in a timely manner:
  1. Needle (the most essential consumable)​
  CheckpointsBefore each use, observe whether the needle is bent or blocked (the needle can be aimed at the light for observation, and if there is no light transmission or poor flow of medication, it indicates blockage); Check if the needle has a barb after use (repeated use can cause skin damage or infection).
  replacement frequency:Single-use(Regardless of visible contamination), it is recommended to replace every injection (no more than 3 days to avoid needle tip passivation and bacterial growth).
  Replacement steps:
① Remove the old needle (rotate the pen cap counterclockwise 90 ° or pull it out directly);
② Install a new needle (align the pen core interface, tighten clockwise to avoid over tightening causing the pen core to break);
③ Exhaust (after using or replacing the pen core, lightly tap the pen holder to make the bubbles float up, adjust the knob to "1 unit", press the injection button until a droplet appears at the needle tip, ensuring no bubbles).
  2. Pen refill (insulin drug carrier)​
  CheckpointsObserve whether the medicine in the pen core is clear (cloudy, discolored, with particles indicating deterioration, and needs to be discarded); Check if the rubber plug of the pen core is intact (without cracks or dents, otherwise it may leak).
  replacement frequencyFollow the instructions or medical advice (usually replace the pen core after use to avoid contamination caused by repeated punctures of the medication).
  PrecautionsUnopened pen refills need to be refrigerated (2-8 ℃), while opened pen refills can be stored at room temperature (≤ 25 ℃) for 4 weeks (refer to the instructions) to avoid freezing (freezing can damage insulin structure).
  3. Push rod and dosage adjustment knob​
  CheckpointsWhen adjusting the knob, it should be smooth and without any jamming (if the rotation is laborious or there is a "click" noise, it may indicate gear wear); The push rod should be pushed at a constant speed (if suddenly accelerated or stopped, the internal spring may fail).
  Maintenance RecommendationsAvoid rotating the knob too forcefully (which may cause gear misalignment); If you find any lag, you can contact the manufacturer's after-sales service for calibration. Do not disassemble it yourself.
  4. Pen cap and sealing ring​
  CheckpointsIs the rubber sealing ring on the inside of the pen cap aging (sticking or cracking can cause poor sealing, evaporation or contamination of the medication); Is the thread between the cap and body of the pen intact (without slipping).
  replacement frequencyCheck the sealing ring every 6-12 months and contact the manufacturer for replacement after aging (other materials such as rubber bands cannot be used as substitutes).
4、 Storage standard: Avoid "hazardous environments" and ensure the safety of medication and equipment
The storage of insulin pens needs to be considered simultaneouslyIntegrity of pen body structureandStability of insulin solutionImproper storage may result in inaccurate dosage or ineffective medication.
  1. Pen without pen refill installed​
  Storage conditionsDry place at room temperature (15-30 ℃), avoid direct sunlight (UV rays can accelerate plastic aging); Stay away from heat sources (such as radiators, stoves) or low temperature environments (<0 ℃, pen body is prone to freezing and cracking).
  tabooDo not put it in the refrigerator (condensation water may cause internal rust or circuit short circuit).
  2. Pen with installed pen core​
  Short term use (within 1 week)Can be stored at room temperature (≤ 25 ℃) (avoid high temperatures, such as in summer when the temperature inside the car is above 30 ℃, which may cause the decomposition of the medicine);
  Long term unused (>1 week)The pen core needs to be refrigerated (2-8 ℃), but it should be taken out and warmed up 30 minutes in advance before injection (to avoid the low-temperature liquid stimulating subcutaneous tissue and causing uneven absorption);
  Travel carryingUse a dedicated insulated box (with built-in ice packs or temperature control devices) to avoid temperatures (such as low temperatures in airplane luggage compartments or high temperatures in deserts).
  3. Special case storage​
  Differences in insulin typesQuick acting insulin (such as aspart insulin) is more sensitive to temperature and requires strict refrigeration; Long acting insulin (such as glargine insulin) is relatively stable, but high temperatures should still be avoided;
  The pen body contains electronic components(such as smart insulin pens): Charge according to the instructions (to avoid damaging the battery due to excessive discharge), and disconnect the charger when storing.
5、 Regular maintenance: professional calibration and functional verification to ensure precise dosage
Even with proper daily maintenance, the mechanical components of insulin pens may still have slight deviations (such as dosage errors>5%) due to long-term use, and regular maintenance is necessaryProfessional calibration and functional verification.
  1. Home self inspection (once a month)​
  Dose accuracy testing: After installing a new refill and exhausting the air, adjust the knob to "10 units", press the injection button on the sterile gauze, and observe the liquid output from the needle tip (normally it should be 10 units of liquid drop volume, about 0.1mL); Repeat 3 times, if the error is>± 1 unit, contact a doctor or manufacturer.
  Display window clarity checkObserve the dose display window under natural light to ensure that the numbers are not blurry or scratched (if blurry, it may be due to aging of the internal reflector and need to be replaced).
  2. Professional maintenance (once every 6-12 months)​
  Hospital/Pharmacy CalibrationBring an insulin pen to the endocrinology department or pharmacy, and use a dedicated dose calibrator (such as a simulated injection device) to detect the deviation between the actual output dose and the set dose (standard: ≤± 5%);
  Component depth inspectionDisassemble the pen body by professional personnel (only authorized maintenance personnel), check gear wear, spring elasticity, push rod stroke, etc., and replace aging parts if necessary;
  Software upgrade (smart pen)If using a smart insulin pen (such as a memory pen with Bluetooth function), it is necessary to regularly connect to the app to upgrade firmware (optimize dosage algorithms or fix bugs).
6、 Common troubleshooting: Quickly solve "minor problems" and avoid "troubles"
Possible issues during the use of insulin pensInaccurate dosage, leakage, and inability to injectFor problems, you can quickly troubleshoot them by following these steps:

Fault phenomenon​
Possible reasons​
solution​
The dose display window is blurry​
Surface stains or aging of internal reflectors
Gently wipe with a soft cloth dipped in water; If it is ineffective, contact the manufacturer to replace the display window component.
Adjustment knob stuck​
Dust or lubricating oil entering between gears and drying up
Dip a cotton swab in a small amount of medical Vaseline (only apply to the gap of the knob) for lubrication; If the lag is severe, send the gear for repair and calibration.
Leakage during injection​
Needle not tightened, pen core rubber stopper aging, or push rod not reset
Tighten the needle again; Replace the pen core; Keep pressing for 3 seconds after injection before pulling out the needle (ensure the medication is injected).
Inaccurate dosage (too much/too little)​
Wear of push rod, deformation of pen core piston or misalignment of dosage knob
Test with a new pen core; If still inaccurate, send the manufacturer to calibrate the push rod or replace the pen body.
Unable to press the injection button​
Push rod stuck by foreign object or spring failure
Check if the pen core is installed properly (insertion will push against the push rod); If the spring fails, the push rod component needs to be replaced.
7、 Attention: Details determine safety, habits lead to health
  Aseptic operationWash hands before injection, avoid disinfecting the pen body directly with alcohol (which may corrode the plastic), and use the needle disposable (repeated use increases the risk of infection and hardening);
  avoid collisionThe insulin pen is a precision instrument, and falling or squeezing may cause internal gear misalignment and pen core breakage;
  Child and pet protectionStore at a high place or in a locked medication box to avoid accidental injection (children may imitate the operation and cause accidents);
  Record and Follow upRecord the time of each replacement of pen refills and needles, and regularly (every 3 months) visit the hospital to check blood sugar levels and evaluate the effectiveness of insulin pen use.
  ConclusionThe maintenance and upkeep of pen insulin syringes are key to ensuring precise administration and ensuring patient safety. By daily cleaning, component inspection, standardized storage, regular maintenance, and quick troubleshooting, the lifespan of the device can be extended and medication risks can be reduced. Patients need to consider maintenance as a "part of treatment" and work together with medical staff to safeguard the "last mile" of blood sugar control.