Polyurethane insulation pipes have good insulation materials and should have low thermal conductivity; It does not deteriorate when exposed to moisture, has good heat resistance, does not corrode metals, is lightweight with many voids; Has a certain mechanical strength and will not be damaged when subjected to external forces; Due to its ease of processing and low cost, today the editor will explain to you the calculation method for its load-bearing capacity.
1: Calculation method for calculating the compressive strength of polyurethane insulation pipes based on their outer diameter specifications and wall thickness (different materials of steel pipes have different tensile strengths)
Pressure=(wall thickness * 2 * tensile strength of steel pipe material)/(outer diameter * coefficient)
2: Calculation method for wall thickness of seamless steel pipe based on its outer diameter and bearing pressure:
Wall thickness=(pressure * outer diameter * coefficient)/(2 * tensile strength of steel pipe material)
3: Method for expressing the pressure coefficient of steel pipes:
Pressure P<7Mpa, coefficient S=8
7<steel pipe pressure P<17.5 coefficient S=6
Pressure P>17.5 coefficient S=4
Formula for calculating the weight of polyurethane insulation pipe support
Outer diameter: D, wall thickness: s; length: m; weight: kg.
Formula: (D-S) * s * 0.02466 * m=kg