A brief introduction to the calculation method for the pressure bearing capacity of polyurethane insulation pipes
Date: 2025-10-12Read: 7

Polyurethane insulation pipes have good insulation materials and should have low thermal conductivity; It does not deteriorate when exposed to moisture, has good heat resistance, does not corrode metals, is lightweight with many voids; Has a certain mechanical strength and will not be damaged when subjected to external forces; Due to its ease of processing and low cost, today the editor will explain to you the calculation method for its load-bearing capacity.

1: Calculation method for calculating the compressive strength of polyurethane insulation pipes based on their outer diameter specifications and wall thickness (different materials of steel pipes have different tensile strengths)

Pressure=(wall thickness * 2 * tensile strength of steel pipe material)/(outer diameter * coefficient)

2: Calculation method for wall thickness of seamless steel pipe based on its outer diameter and bearing pressure:

Wall thickness=(pressure * outer diameter * coefficient)/(2 * tensile strength of steel pipe material)

3: Method for expressing the pressure coefficient of steel pipes:

Pressure P<7Mpa, coefficient S=8

7<steel pipe pressure P<17.5 coefficient S=6

Pressure P>17.5 coefficient S=4

Formula for calculating the weight of polyurethane insulation pipe support

Outer diameter: D, wall thickness: s; length: m; weight: kg.

Formula: (D-S) * s * 0.02466 * m=kg