Detailed introduction of formaldehyde fumigation sterilizer, application principle and scope of formaldehyde fumigation sterilizer
Date: 2015-06-08Read: 5

formaldehydeFumigation sterilizerApplicable tomicroorganismThe disinfection and sterilization products in the clean areas of laboratories and pharmaceutical factories are designed in a simple waydisinfectSterilization. When the instrument is working, it fills the space to be disinfected with formaldehyde gas, and after a certain period of time, it kills the exposed surface of the spacebacteriaandvirus.

formaldehydeFumigation sterilizerprinciple

By controlling pressure and temperature, alcohol and formaldehyde are excited to become a chemical mixture gas. The penetration of the mixture gas is increased by changing the pressure of water vapor, and the sterilization ability of the mixture gas is enhanced by temperature control. Working temperature: 60 ℃ or 78 ℃,Sterilizing agent3% alcohol+2% formaldehyde aqueous solution+95% distilled water.

formaldehydeFumigation sterilizerInstructions for use

Generally,Formaldehyde fumigationThe sterilizer is installed in the ventilation area of the ventilation system. When formaldehyde fumigation is required, pour 40% of the required amount of formaldehyde into the heating device, turn on the return air system, turn off the system's fresh and exhaust air, let the gas diffuse for 30 minutes, and then stop the return air system.Formaldehyde fumigationAfter 12 hours of disinfection, 25% ammonia water is added to the efficiency box of the combined air cabinet. The return air system is opened for 6 hours of circulation, and then the fresh air and exhaust air are opened for 4 hours until the steam is completely replaced by clean air.

formaldehydeFumigation sterilizerScope of application

Formaldehyde fumigation sterilizerSuitable for clean production workshops, packaging rooms, microbiology laboratories, and other places with strict requirements for the quantity of spatial microorganisms. These places include pharmaceutical companies, food companies, testing and inspection companies, and so on.