Laboratory microfiltration/ultrafiltration/nanofiltration/reverse osmosis membrane separation test device
Date: 2020-08-28Read: 6
   Membrane separation test device

This device is an experimental equipment designed for various researchers to conduct membrane separation experiments. It is equipped with one or two small roll type membrane modules, which can be used in series or parallel with single or double modules; By replacing membrane components of different specifications, low-pressure reverse osmosis, nanofiltration, ultrafiltration, and microfiltration tests can be conducted separately. The feature is that the system is compact, compact, and easy to operate on the desktop; No leakage, low liquid flow rate; Adopting imported standard membrane components with reliable performance; Convenient component replacement and easy experimental operation. This equipment is mainly used to determine the technical process parameters for material liquid separation and purification, as well as the selection of membrane materials and membrane types, to determine the effect achieved by membrane separation, and to provide design basis for industrial systems.







Characteristics of membrane separation test device


This device is equipped with complete process parameter detection instruments, and the system is equipped with a flow display and metering system - concentrated water (liquid) flow rate, product water (clear liquid) flow rate; Conductivity detection indicator instrument - measures the conductivity of raw water (liquid) and pure water (permeate), as well as the working temperature parameters of the liquid; Work pressure indicator instrument. The shell is made of stainless steel frosted plate, which is beautiful and hygienic.


Various roll type membrane elements such as reverse osmosis, nanofiltration, ultrafiltration, and microfiltration can be installed according to experimental needs for the concentration, desalination, separation, purification, clarification, sterilization, and purification of feed liquids. They can be widely used in pharmaceutical, food and beverage, chemical, plant extraction, biological agents, environmental water treatment, and other fields, especially suitable for universities, research institutions, enterprise R&D centers, and small-scale production.


Our company can provide imported membrane components and membranes with various materials and molecular weight cut-off according to user needs. We can also provide you with laboratory pure water and ultra pure water equipment, as well as membrane separation equipment for reverse osmosis, nanofiltration, ultrafiltration, and microfiltration in both Chinese and industrial production scales.



Technical parameters of roll film experimental equipment:


Roll film experimental equipment

Basic parameter performance

model

HPLM-1812

Membrane characteristics available:

Ultrafiltration membrane materials: PES, PVDF, PS, PAN, etc.

Molecular weight cut-off of ultrafiltration membrane: 1000-200000MW

Microfiltration membrane materials: CA, PS, PAN, PVDF, PP, PTFE, etc.

Pore size of microfiltration membrane: 0.1-1 µ m

Nanofiltration membrane material: Polyacyl * * * composite membrane

Molecular weight cut-off of nanofiltration membrane: 150-500MW

Reverse osmosis membrane material: polyimide * * * composite membrane

Desalination rate: 98-99.5%

General specifications for membrane components

1812

Membrane area of the component

About 0.4 square meters

work pressure

60-120PSI

Adapt to working temperature

5-45℃

Adapt to pH range

4--10

Small cycle volume

1L

Device overcurrent rate

0.5-5L/h

Applicable mother liquor volume

5-100L

Work flow

0.75-1LPM

Working Voltage

220V

Pipeline and fittings

PE 1/4

Overall dimensions

600X600X600

power

100-200G diaphragm pump

Models and application areas of HP roll/flat ultrafiltration membranes

Membrane Model

Molecular weight cut-off

Dalton

Pure water flux lmh

@25℃ 1.0Mpa

Application field

PES1

1000

40

Chondroitin sulfate concentration; Lysozyme concentration; Dye purification; Purification, concentration, and fractionation of organic compounds; Protein concentration and separation; Removal of pigments from sugars; Heat source removal, etc.

PES3

3000

65

PES5

5000

100

PES8

8000

130

PES10

10000

150

Starch and amylase concentration; Cellulase and phytase concentration; Transaminase concentration; Concentrated carrageenan; Protein concentration and separation; Whey concentration; Oil-water separation; Clarification of pharmaceutical intermediates; Fructose clarification; Silicon powder recycling; Clarification of chlorogenic acid and baicalin; Separation, concentration, and purification of blood and biological products; Extraction and refinement of traditional Chinese medicine preparations; Purification of antibiotics and interferons; Purification, concentration, and refinement of fermented products; Clarification and sterilization of fruit juice and alcoholic beverages.

PES20

20000

200

PES30

30000

240

PES50

50000

260

PS20

20000

280

PS50

50000

350

PVDF50

50000

400

PVDF100

100000

500

PS=Polysulfone PES=Polyether Sulfone PVDF=Poly450 Vinyl Fluoride PAN=Polypropylene***

Types and Applications of Nanofiltration Membrane

Nanofiltration membrane (NF) is a special and promising type of separation membrane, with a molecular weight cut-off of approximately 80-1000 and a pore size of about 1 nanometer. The surface separation layer of nanofiltration membrane is composed of polyelectrolytes, which have electrostatic interactions with ions and therefore have a certain retention rate for inorganic salts.

Membrane Model

rejection rate

MgSO4

Pure water flux lmh

@25℃ 1.0Mpa

Application field

NF1

98%

65

Low temperature concentration and ash removal of antibiotic drugs

Desalination and concentration of dyes, replacing salt precipitation and acid precipitation

Concentration of dilute sugar solution and purification of oligosaccharides

Extraction and concentration of bioactive ingredients

Pharmaceutical intermediate concentration, collagen concentration

Softening of water quality
Separation and purification of organic acids and amino acids

Recovering acid and alkali from waste acid and alkali

Wastewater treatment and recycling

NF2

95%

100

NF1, NF2: * * * Composite membrane


We have over 20 years of experience in manufacturing and applying process separation membranes, relying on high-quality membrane products from Europe and America to assist in liquid separation, concentration, purification, and clarification; Provide clean, environmentally friendly, and simple process solutions. Our products have won the trust of universities and enterprises such as Tsinghua University, Jilin University, FAW Group, Changchun Henkel, Tianjin PPG, Zixin Pharmaceutical, Tonghua Dongbao, etc.

Our partners include GE, Hydranautics, Dow Chem, Koch, Pantair, Synder, and others.