What instrument is used to detect the physical properties of the five layer co extruded infusion film (1) and bag
The quality of the five layer co extruded infusion film (1) and bag is related to the product quality within the shelf life. By using the five layer co extruded infusion film (1) and bag detection instrument from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd., the sterilization adaptability, usage adaptability, and physical indicators of the five layer co extruded infusion film (1) and bag can be conveniently, quickly, and economically detected, enabling the quality detection of the five layer co extruded infusion film.
This article will introduce the quality solution for the five layer co extruded infusion film (1) and bag using our company's professional pharmaceutical packaging material testing instrument in accordance with the requirements of YBB00112005-2015 "Five layer co extruded infusion film (1) and bag".

Intelligent Load Voltage Tester
Five layer co extruded infusion film (1), bag temperature adaptability experimental device;
Experimental objective: As a large infusion packaging, high temperature disinfection is required, so temperature adaptability is an important testing item.
Standard requirement: YBB00112005-2015 "Five layer co extruded infusion film (1), bag" requires that the sample be placed between two parallel plates, subjected to an internal pressure of 67kPa, and maintained for 10 minutes without any liquid leakage.
Testing Equipment: Intelligent Load Voltage Tester ZY-500 from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd

Drop tester
Five layer co extruded infusion film (1), bag anti drop tester DL-1000;
Experimental objective: In the event of force majeure during transportation, storage, and use of large infusion packaging bags, there are high requirements for the anti drop index of the five layer co extruded infusion film (1) and bag.
Standard requirement: According to the drop height in Table 1, drop onto a hard and rigid smooth surface without any rupture or leakage.
Testing equipment: Drop testing machine DL-2000 from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd

Puncture force tester
Five layer co extruded infusion film (1), bag transparency experimental device;
Experimental objective: Transparency is an important detection indicator for five layer co extruded infusion film
Standard requirement: Illuminate with a light intensity of 2000-3000lx (avoid exposing the eyes of the test personnel), observe and distinguish it from the control bag
Testing equipment: Standard light source from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd
Five layer co extruded infusion film (1), bag puncture force tester CCY-02;
Experimental objective: The puncture force reflects the mechanical properties of the five layer co extruded infusion film (1) and bag,
Standard requirement: At a speed of 200mm/min ± 20mm/min, the puncture force of the plastic puncture device at the puncture site of the puncture bag shall not exceed 100N, and the puncture force of the metal puncture device shall not exceed 80N.
Testing Equipment: Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd. Puncture Force Tester CCY-02
Five layer co extruded infusion film (1), bag puncture device retention and insertion point non permeability device;
Experimental objective: Five layer co extruded infusion film (1), bag puncture device retention, and insertion point impermeability are important testing indicators for evaluating the quality of rubber plugs and bottle caps
Standard requirement: Take several liquid filled bags to the indicated capacity, first puncture the insertion point of the bag with a puncture device that meets the requirements, and then remove the puncture device at a speed of 200mm/min ± 20mm/min. The separation force of the plastic puncture device should not be less than 5.0N, and the separation force of the metal puncture device should not be less than 1.0N. After removing the puncture device, place the bags between two parallel plates, apply an internal pressure of 20kPa, and maintain it for 15 seconds. There should be no liquid leakage at the insertion point.
Testing equipment: CCY-02 puncture force tester, ZY-500 intelligent pressure tester, and metal puncture needle from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd.
Five layer co extruded infusion film (1), bag injection point sealing device CC-10;
Experimental objective: Good sealing of injection points can avoid secondary contamination of large infusion drugs after dispensing, and is also an important detection indicator.
Standard requirement: Use an injection needle with an outer diameter of 0.6mm to puncture the injection site and maintain it for 15 seconds. After removing the injection needle, place the bags between two parallel plates and apply an internal pressure of 20kPa for 15 seconds. There should be no leakage at the injection site.
Testing equipment: Sealing experimental device for injection points of Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd
Five layer co extruded infusion film (1), bag temperature suspension force device XG-80;
Experimental objective: To evaluate the tensile strength of the lifting ring at the bottom of the five layer co extruded infusion film (1) and the bag temperature suspension force response of the book large infusion,
Standard requirement: Take several liquid filled bags to the indicated capacity, apply tension to the lifting ring according to Table 2, and do not break within 60 minutes.
Testing equipment: Suspension force experimental device XG-80 from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd.
Five layer co extruded infusion film (1), bag tensile strength tester YYB-03;
Experimental objective: Five layer co extruded infusion film (1) and bag tensile strength are routine testing items
Standard requirements: According to the tensile performance measurement method (YBB00112003-2015), the sample should be selected as type II, the test speed (no-load) should be selected as 500mm/min ± 50mm/min, and the average longitudinal and transverse tensile strength should not be less than 20MPa.
Testing equipment: Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd.'s pharmaceutical packaging tearing force tester
Five layer co extruded infusion film (1), intelligent electronic tensile testing machine and heat sealing instrument for bag heat sealing strength testing;
Experimental objective: The five layer co extruded infusion film (1) and bag heat sealing strength have a direct impact on packaging integrity. Therefore, this standard has clear provisions for them.
Standard requirement: According to the method for measuring the heat sealing strength of composite bags (YBB00122003-2015), the average value of the heat sealing area shall not be less than 20N/15mm.
Testing equipment: RFY-03 heat sealing instrument and DLS-07 intelligent electronic tensile testing machine from Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd
Five layer co extruded infusion film (1), bag transmittance haze tester;
Experimental objective: The five layer co extruded infusion film (1) and bag transmittance are important testing indicators that require the quality of the material itself
Standard requirement: The transmittance measured at 450mm shall not exceed 75%.
Testing equipment: Jinan Sanquan Zhongshi Experimental Instrument Co., Ltd. transmittance haze tester WGT-S
In summary, this is a brief introduction to the solution for the five layer co extruded infusion film (1) and bag provided by Jinan Sanquan Experimental Instrument Co., Ltd. in accordance with the requirements of YBB00112005-2015 "Five layer co extruded infusion film (1) and bag". For detailed solutions and methods, please call Sanquan Zhongshi.
Five layer co extruded infusion film (1), bag is a type of large infusion packaging bag, which uses professional laboratory testing equipment to analyze product quality, expected shelf life effectiveness, and packaging design rationality. Fundamentally solve the quality problems of infusion bags.