Welcome Customer !

Membership

Help

Nano Micro (Guangzhou) Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Article

Nano Micro (Guangzhou) Instrument Technology Co., Ltd

  • E-mail

    nanowetech@163.com

  • Phone

    13928824355

  • Address

    No. 579 Jingang Avenue, Nansha District, Guangzhou City

Contact Now
Process and advantages of microfluidic chips
Date: 2024-05-28Read: 7
The Nanowetech rapid nanomedicine manufacturing system utilizes microfluidic chip hybrid technology, which can be used for the rapid self-assembly of materials such as nanoliposomes and polymer nanoparticles.
Process:
1. Load the aqueous phase or the aqueous phase containing dissolved API and the organic phase solvent containing dissolved nanoparticle precursors (such as lipid components) into two syringes, and then use a pump to inject the two syringes into the two inlets of the Nanowetech microfluidic chip.
2. In laminar flow, the two phases will not mix completely immediately.
3. The microstructure in micrometer scale channels can repeatedly control the mixing of two phases.
4. Rapid, controllable, and uniform mixing technology enables uniform preparation of nanomedicine.
5. This method is relatively simple, fast, mild in conditions, and easy to achieve production scaling up.
The advantages of using microfluidic control to prepare nanoparticles such as LNP include:
1. Shorten mixing time, achieve millisecond mixing efficiency, and complete the preparation of mL level samples within seconds;
2. By precise flow rate control, monodisperse nanoparticles of various particle sizes can be achieved;
3. Improve uniformity and high monodispersity (PDI usually below 0.2);
4. Good repeatability in multiple preparations;
5. The method is relatively simple, fast, mild in conditions, does not generate high-energy shear forces, and does not easily damage bioactive components;
6. Later stage can be scaled up, high-throughput and continuous production.