The tapping type sterile homogenizer is widely used for homogenization treatment of animal tissues, biological samples, etc. It can be applied in various fields such as food, medicine, cosmetics, clinical, molecular, toxin and bacterial detection, especially suitable for temperature controlled sterilization function sterile homogenizers.
During the use of the tapping type sterile homogenizer, the following aspects should be noted:
1) The storage of instruments and homogenization bags should avoid direct sunlight exposure, especially the homogenization bags should be stored in a place without sunlight or UV exposure to prevent aging.
2) Please do not open the homogenizer door casually while working on the hammer plate to prevent the sample liquid from overflowing. The equipment should automatically stop running according to the "on/off" mode. After closing the door, press the "on/off" button again, and the equipment will automatically complete the remaining work. Do not reverse the operation.
3) If the instrument is not used for a long time, the power should be cut off and the plug should be unplugged. Prevent the aging of electronic components inside the sterile homogenizer.
4) The power plug must be securely plugged in. If it becomes loose, it may affect the computer controller and cause it to crash. If a crash occurs, please turn off the rear power switch and restart it after 3 minutes of shutdown.
5) Before operating the machine, please carefully check for any foreign objects inside the homogenization box to avoid malfunctions and damage to the homogenization bag during operation.
6) Hard and sharp substances such as lumps, bones, and ice should not be used to avoid damaging the homogeneous bag.
7) The bottom of the homogenizer door is designed to be empty to prevent accidental rupture of the homogenization bag and facilitate cleaning of spilled material. A water tray can be placed at the bottom, so please do not insert your hands from the bottom when the instrument is running to avoid scratching your fingers. Do not open the homogenizer door during operation, as it may cause unnecessary damage.
8) When the quantity is small and the speed needs to be increased, or when the homogeneous fibers are relatively tough, the distance between the tapping plate and the visible window can be adjusted with the knob at the back to achieve better homogenization effect. Pay attention to adjusting the distance to avoid damage to the sterile homogenizer such as air strikes.