In addition to being used in biopharmaceuticals, natural (health) foods, and cosmetics, traditional Chinese medicine cell wall breaking machines are also widely used in various industries related to powder applications, such as building materials (preparation of ultrafine water slag, fly ash, etc.), chemical, metallurgical, environmental protection (brick making from garbage micro powder, etc.), electronics (paddle materials, graphite emulsion, etc.), etc.
The maintenance and upkeep of the traditional Chinese medicine cell wall breaking machine are crucial for ensuring the stable operation of the equipment and the quality of drug extraction. The following are maintenance and upkeep suggestions for the traditional Chinese medicine cell wall breaking machine:
Regular inspection and replacement of vulnerable parts: Regularly inspect the wear of key components such as blades, bearings, and transmission systems, replace worn parts in a timely manner, and ensure the wall breaking effect and accuracy of the equipment.
Cleaning and disinfection: After each use, promptly clean and disinfect the cell wall breaking machine and its accessories to remove residual Chinese medicinal materials and impurities, and prevent cross contamination.
• Bearing temperature monitoring: Regularly check the bearing temperature. When the temperature exceeds 50 ℃, the machine should be stopped for inspection and troubleshooting.
• Cooling system maintenance: Regularly remove dust from the radiator, check the coolant level, and replace the coolant regularly to ensure good heat dissipation.
Electrical system inspection: Regularly check the insulation layer of cables to avoid aging and short circuits.
Lubrication system maintenance: Regularly inspect and replace lubricating grease to ensure the normal operation of the equipment's lubrication system and reduce wear and failure.
• Check equipment connections: Regularly inspect the connection parts such as power lines, feed pipes, and discharge pipes to ensure that the connections are tight and free of looseness.