Online boiler water hardness tester - capable of monitoring multiple parameters simultaneously, providing more comprehensive water quality information
Date: 2025-12-29Read: 5

【 Model recommendation: TH-GL02, a manufacturer of meteorological and environmental monitoring instruments and equipment. Yunjing Tianhe supports customized services for merchants. You can rest assured when choosing Shandong Yunjing Tianhe. 】 Online boiler water hardness tester - capable of monitoring multiple parameters simultaneously, providing more comprehensive water quality information. The online boiler water hardness tester is widely used in boiler systems in industries such as power, chemical, metallurgy, and textile, providing important guarantees for enterprise safety production and energy conservation and emission reduction. Real time monitoring of boiler inlet water hardness to ensure that the inlet water quality meets the requirements of boiler operation and prevent boiler failure caused by water quality issues. Boiler water replenishment monitoring: During the boiler water replenishment process, real-time monitoring of the hardness of the replenishment water is carried out, and the operating parameters of the water treatment equipment are adjusted in a timely manner to ensure stable water quality of the replenishment water. Monitoring of circulating water system in boiler circulating water system, real-time monitoring of the hardness changes of circulating water, to prevent the formation of scale and equipment corrosion caused by excessive hardness. Select appropriate measurement accuracy based on actual needs to ensure accurate and reliable detection results. For scenarios that require quick response, a detector with fast response speed should be selected. Stability and reliability: Choose a detector that can operate stably for a long time in harsh industrial environments to ensure data accuracy and equipment reliability.

7.jpg

1、 Product Introduction
Online water quality analyzer is an instrument that can monitor water hardness and chloride ions online, and can quickly and accurately record key parameters in water bodies. At the same time, the instrument supports the expansion of water quality multi parameter sensors, which can be combined and configured according to different needs and applications, record and store historical monitoring data and alarm history records, and support the export of historical data. The RS485 interface supports the MODBUS-RTU communication protocol, making it convenient for users to communicate freely. It can connect and transmit data with devices such as PLC, DCS, configuration software, DTU, etc.


2、 Application Fields

1. Factory boiler water quality monitoring: used to prevent the formation of scale, prevent equipment corrosion, and ensure equipment safety.

2. Groundwater monitoring: used to monitor parameters such as pH value, conductivity, temperature, etc. of groundwater, in order to timely detect and solve water quality problems.

3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, in order to take timely pollution control measures.

4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, in order to timely detect and control marine pollution.

5. Sewage treatment: used to monitor the water quality parameters of sewage, such as pH value COD、 Ammonia nitrogen and other substances are used to control and regulate the sewage treatment process.

6. Industrial production: used to monitor the water quality status in the industrial production process, such as pH, conductivity, dissolved oxygen and other parameters, in order to adjust the process in a timely manner and ensure product quality.

7. Water treatment plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water, ensuring the safety and hygiene of tap water.

8. Scientific research: used for water quality monitoring in the field of scientific research, such as eutrophication of lakes, climate change, and other studies.


3、 Product Features

1. High reliability: suitable for long-term work in outdoor environments, with stable measurement and strong anti-interference ability.

2. Flexible and portable: Each probe can be freely combined and replaced independently, plug and play.

3. Scalability: Multiple sensors can be freely combined.

4. Multiple applications: rapid on-site measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipeline water.

5. Resilient shell: ABS+PC material, corrosion-resistant, capable of long-term continuous normal operation.

6. Compact structure: can be installed in smaller sizes.

7. Communication connection: RS485 expansion interface, isolated master/slave interface for independent communication.


4、 Technical parameters of multi parameter water quality analyzer


display output 4.3-inch touch screen with strong LED backlight, operable under direct sunlight
power supply DC power supply: DC12V
power consumption The power consumption of the instrument is about 12V/1W
Sound output buzzer
communication protocol Standard RS485 Modbus RTU protocol and device master/slave transmission channel support
Main materials ABS+PC material
Storage temperature -20 to 70 ℃
Operating temperature -10 to 50 ℃
Protection level IP65
size 175mm * 140mm * 49mm (length x width x height)
weight About 0.5KG


5、 Sensor parameters


model name measurement range principle measurement accuracy resolution Is it standard remark
S1S cod 0~1000mg/ L UV254 absorption method ±5%, ±0.3℃ 0.1mg/L
COD turbidity integrated; Self cleaning with brush and temperature compensation
turbidity 0~400NTU scattered light method ± 1%, ±0.3℃ 0.1NTU
S2 Water hardness 0~1000.0mg/L Contact electrode method ± 10% of the reading; ±0.3℃ 0.1mg/L √
S3 pH 0~14(ph) Electrochemistry (salt bridge) ± 0.1PH; ±0.1℃ 0.01
Warm compensation
S4 residual chlorine 0~5.00 mg/L Ion selective electrode method ± 5% of the reading; ±0.3℃ 0.01mg/L
Integrated residual chlorine pH; Accuracy at flow rates of 0.42m/s-0.85m/sBest; Warm compensation
pH 0~14(ph) Electrochemistry (salt bridge) ± 0.1PH; ±0.1℃ 0.01
S5 ammonia nitrogen 0~1000mg/l Ion selective electrode method 10% of the reading, ± 0.5 ℃ 0.01mg
Ammonia nitrogen pH integrated; Warm compensation
pH 0~14(ph) Electrochemistry (salt bridge) ± 0.1PH; ±0.1℃ 0.01
S6 ORP -1500mv~1500mv Electrochemistry (salt bridge) ± 6mv 1mV

S7 conductivity 0~10000uS/cm Contact electrode method ± 1.5%; ±0.1 °C 1uS/cm
Warm compensation
S7H High range conductivity 0~30000μS/cm Contact electrode method ± 1.5%; ±0.1 °C 1uS/cm
High range conductivity TDS salinity integrated sensor; Warm compensation
TDS 0-10000ppm Contact electrode method ± 1.5%; ±0.1 °C 1ppm
salinity 0-10000ppm Contact electrode method ± 1.5%; ±0.1 °C 1ppm
S8 dissolved oxygen 0~20mg/L Fluorescence lifetime method ±2%, ±0.3℃ 0.01mg/L
Warm compensation
S9 turbidity 0~1000NTU scattered light method ±1% , ±0.3℃ 0.1NTU
Warm compensation
S9S Self cleaning turbidity 0~1000NTU scattered light method ±1% , ±0.3℃ 0.1NTU
Self cleaning with brush; Warm compensation
S10 suspended solids 0~2000mg/L scattered light method ± 5% (depending on sludge homogeneity) 0.1mg/L

S11S sludge concentration 0~20.000g/L scattered light method ± 5% (depending on sludge homogeneity) 0.001g/L
Self cleaning with brush
S14 chloride ion 0-3500.0mg/L Ion selective electrode method ±5%; ±0.3℃ 0.1mg/L √
S15S chlorophyll 0~400ug/L fluorescence method R²>0.999 0.01ug/L
Self cleaning with brush; Warm compensation
S16S blue-green algae 0~200.0Kcells/mL fluorescence method R²>0.999 0.1Kcells/mL
Self cleaning with brush
S17S 水中油 0~60ppm fluorescence method 0.1ppm 0.01ppm
Self cleaning with brush
S20 transparency 50~1000mm scattered light method ± 5% (depending on sludge homogeneity) 1mm
Warm compensation
S21 water temperature −20℃~85℃ High precision digital sensor ±0.1℃ 0.1℃