What are the contents of injection water equipment:
Injection water refers to water that meets the requirements of the Chinese Pharmacopoeia for injection water. The injection water is distilled water or deionized water obtained by distillation, so it is also weighed as distilled water. In order to effectively control microbial contamination and at the same time control the level of bacterial endotoxins, two major characteristics have emerged in the design and manufacturing of purified water and injection water systems: one is the increasing use of disinfection in the system/Sterilization facilities; The second is that the pipeline distribution system has evolved from traditional water supply pipelines to circulation pipelines.
Injection water equipment is composed of water treatment equipment, storage equipment, distribution pumps, and pipeline networks. There is a possibility of external pollution caused by raw water and external factors in the water production system, and the pollution of raw water is the main external source of pollution in the water production system. The United States Pharmacopeia, European Pharmacopoeia, and Chinese Pharmacopoeia all require that raw water for pharmaceutical use must meet at least the quality standards for drinking water. If the drinking water standard cannot be met, pre purification measures should be taken first. Due to E. coli being a clear indicator of water pollution, there are clear requirements internationally for E. coli in drinking water. Other contaminating bacteria will not be further classified and will be included in the standardThe total number of bacteria "refers to the limit set by China for the total number of bacteria100a/mlThis indicates that there is also microbial contamination in the raw water that meets the drinking water standards, and the main contaminating bacteria that endanger the water production system are gram-negative bacteria. Other factors such as the lack of protective measures at the exhaust outlet of storage tanks or the use of inferior gas filters, as well as water backflow from contaminated outlets, can also lead to external pollution.
Comparison of purified water, injection water, and sterile injection water:
Comparison of purified water, injection water, and sterile injection water:
project |
Purified Water |
Water for Injection |
Sterile injection water |
source |
Prepared by distillation, ion exchange, reverse osmosis or other methods |
Purified water obtained by distillation |
Injection water is prepared according to the injection production process |
trait |
Colorless clear liquid, odorless and tasteless |
Colorless clear liquid, odorless and tasteless |
Colorless clear liquid, odorless and tasteless |
pH |
PH value 4.2-7.6 |
PH value 5.0-7.0 |
PH value 5.0-7.0 |
Chloride, sulfate, and calcium salts |
No turbidity is allowed |
No turbidity is allowed |
No turbidity is allowed |
nitrate |
0.000 006% |
0.000 006% |
0.000 006% |
nitrite |
0.000 002% |
0.000 002% |
0.000 002% |
ammonia |
0.000 03% |
0.000 02% |
0.000 02% |
carbon dioxide |
No turbidity is allowed |
No turbidity is allowed |
|
oxidizable substance |
Pink must not disappear |
Pink must not disappear |
Pink must not disappear |
non-volatile matter |
The residual residue shall not exceed 1mg |
The residual residue shall not exceed 1mg |
The residual residue shall not exceed 1mg |
heavy metal |
0.000 03% |
0.000 03% |
0.000 03% |
Microbial Limit |
The total number of bacteria, molds, and yeasts shall not exceed 100 per 1ml |
The total number of bacteria, molds, and yeasts shall not exceed 10 per 1ml |
Not checking microbial limits |
bacterial endotoxin |
not required |
The content of endosmycin in 1ml should be less than 0.25EU |
The content of endosmycin in 1ml should be less than 0.25EU |
Comply with the relevant regulations under the injection item |
not required |
not required |
requirement |
category |
Solvent, diluent |
solvent |
Solvent, flushing agent |
storage |
Store in a sealed container |
Store in a sealed container |
Store in a sealed container |
Shanghai Binrun SupplyUltrapure water equipmentafter-sales serviceservice
1. Warranty commitment: The product is covered by a one-year warranty from the date of successful debugging. If the product is not caused by human factors during the warranty period, it will be repaired free of charge.
2. Debugging commitment: After the water production equipment provided and installed has been installed and passed on-site pressure testing and debugging, it can only leave the site with the consent and signature of the representative of the demander.
3. Training commitment: Technical personnel can be sent to assist and guide installation and debugging according to the requirements of the demand side; During the trial operation, train the relevant operators of the demand side until the product operates normally.
4. Repair commitment: In case of equipment malfunction, on-site service will be provided within 12-24 hours upon receiving notification.
5. Lifetime commitment: After the product warranty period ends, we will provide you with lifetime service and paid accessories.
6. Accessory commitment: We can provide timely and complete accessory services both inside and outside the warranty period.
Last Video: Pharmaceutical purified water equipment
Next Video: On site installation diagram of purified water equipment