The adjustment of filling volume of gynecological gel filling machine is a key step to ensure product quality and production efficiency. The following are the steps and precautions for adjusting the filling volume of gynecological gel filling machine:
1、 Preparation work
1. Ensure the stability of the equipment: before adjusting the filling volume, ensure that the gynecological gel filling machine is stably placed on the horizontal ground, and all connectors are fastened without looseness.
2. Cleaning and Inspection: Clean the equipment to ensure that there are no residues or impurities inside the filling machine, and check whether all components are intact and undamaged.
2、 Manually adjust the filling amount
1. Open the control panel: open the control panel of the gynecological gel filling machine, turn on the power switch, and make the equipment in working status.
2. Adjust the pump head seal: Manually adjust the pump head seal to control the flow rate by adjusting the compression degree of the pump head during operation. The compression amount of the pump head seal can be appropriately increased or decreased as needed to achieve the desired filling volume.
3. Adjust valve opening: Manually adjust the valve opening of the filling machine to further regulate the flow rate by adjusting the size of the valve opening. The larger the valve opening, the greater the flow rate: the smaller the valve opening, the smaller the flow rate.
4. Set up flow meter: If the device is equipped with a flow meter, the filling volume can be accurately controlled by setting the value of the flow meter head. According to the target filling volume, set the value of the flowmeter head to ensure the accuracy of the filling volume.
3、 Automatic adjustment of infusion volume
If the gynecological gel filling machine is equipped with an automatic control system, the filling volume can be automatically adjusted through the following steps:
1. Activate the automatic control system: Turn on the automatic control system and select the automatic operation mode of the filling machine.
2. Set target infusion volume: Set the target infusion volume by inputting parameters or following a preset program. The target injection volume can be flexibly adjusted according to production needs.
3. Automatic adjustment: The filling machine will control the on/off status of components such as flow meters and valves according to preset programs, and automatically adjust the filling volume. When the flow meter reading is equal to or close to the set filling amount, the automatic control system will stop filling and complete the filling process.
4、 Precautions
1. Accuracy control: When adjusting the filling amount, attention should be paid to the accuracy of the adjustment to avoid excessive or insufficient adjustment that may cause product quality problems.
2. Program setting: When automatically adjusting the filling amount, it is necessary to ensure that the set program is correct and error free to avoid affecting the filling effect.
3. Equipment inspection: Before and after adjusting the filling volume, it is necessary to inspect the equipment to ensure that all components operate normally without any abnormalities.
Through the above steps and precautions, the filling volume of gynecological gel filling machine can be effectively adjusted to ensure product quality and production efficiency.