Several situations where the fully automatic vacuum feeding machine cannot suction the material and their solutions
Date: 2023-09-18Read: 4
The fully automatic vacuum feeder transports powders, pigments, particles, tablets, capsules, crops, small parts, etc. through pipelines under the input of compressed air. It has the characteristics of simple installation, easy operation, no leakage and no dust flying during the conveying process. This machine is widely used in industries such as pharmaceuticals, food, chemicals, industry, and agriculture.
Below, the editor will briefly introduce several situations and solutions where the fully automatic vacuum feeding machine cannot suction the material:
1. Software difficulties in the anti blowing system
Solution reference: Single pulse anti blowing system software with better processing characteristics should be produced. For detailed key points, please feel free to provide more information.
2. Slow opening of gate valve caused by insufficient cylinder pressure
Solution reference: Use to increase the air pressure
3. Excessive residual material in the pipeline
Solution reference: In long and high transportation loads, there may be excessive residual materials in the pipeline, and a system software for removing residual materials in the pipeline should be designed.
4. Difficulties in pipeline connection
Solution reference: Check if the pipeline, intermediate pipe clamp of the silo, and hard connection are tightened, which may cause system software leakage and result in insufficient vacuum value, endangering feeding.
5. Habitual non feeding leading to material blockage in the filtering device
Solution reference: The key reason is that the total filtering area and precision of the filtering device are not sufficient. In this case, a filtering device with good characteristics should be replaced, which should have high-quality characteristics such as easy to blow off smoke and dust, moisture and oil resistance, stronger total filtering area, and stronger filtering precision, such as polyester coated sub membrane filter element and titanium sintered filter element.
6. Non feeding caused by blockage of the filtering device
Solution reference: Remove the filter element, blow it clean with compressed air, and place it in an ultrasonic cleaner for 30 minutes with a standard load.