Welcome Customer !

Membership

Help

Shanghai Hujing Medical Equipment Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Video
Video

Shanghai Hujing Medical Equipment Co., Ltd

  • E-mail

    2462408924@qq.com

  • Phone

    13701933845

  • Address

    No. 6, Lane 358, Wencheng Road, Songjiang District, Shanghai

Contact Now

Handheld dust particle counter

02.28,20255

Brief Introduction

Y09-3016EHandheld air dust particle counter

Overview

This product adopts a color LCD touch screen and is a handheld dust particle counter designed with this feature.

Technical Specifications

1. Compliant with JJF-1190-2008 dust particle counter calibration specifications:

2. Self purification time ≤ 10 minutes

3. Measurement repeatability relative deviation ≤± 10%

4. Particle size distribution error

5. Particle concentration indication error

6. Sampling flow rate and error: 2.83L/min ≤± 5%

7. Measurable particle size range: 0.3,0.5,1,3,5,10um, divided into 6 particle size channels, with a signal-to-noise ratio of 0.3um ≥ 2.5:1

8. Maximum measurable particle concentration: ≤ 30K particles/L

9. Current DC7.2V, 1800mAh

technical indicators

Test particle size

0.3, 0.5,1,3,5,10μm

light source

laser diode(Lifespan greater than 30000 hours)

flow quantity

2.83 liters per minute (0.1 cfm)

Counting efficiency

50±10%@0.3μm, 100±10%@0.5μm

Measurement of repeated relative deviation

≤±10%

sampling time

User self setting (1 point to 99 points)

sampling delay

User self setting (1 point to 99 points)

sampling frequency

1 to 99 times or continuously

alarm level

Class100~ Class300, 000 level (FED209E standard) or 5-9 level (ISO14464-1 standard)

test method

single/Repetitive/continuous/timed/average

Data memory capacity

1000 sets of measurement data

Error indication

Exceeding maximum count, laser power attenuation, exceeding calibrated flow rate(>± 5%), low battery level

communication interface

USB

Maximum communication speed

12MBPS

Charging time

Charging takes 3 hours and 12 hours

self-cleaning time

≤10min

Maximum concentration

'+/-5% at 2000000 particles/ft3 (71000 Particle/L)

Screen display mode

LCD touch screen

Printing method

External printer, configurationEpson ribbon

Sampling location number

1000 sets

counting mode

Cumulative number, interval,

electricity source

RechargeableNi MH battery (6V/2500mAH) or AC adapter (input 100-240V)

Battery working time

Continuous testing time greater than6 hours

Overall dimensions

220*40*120mm

heavy quantity

1kg

environmental conditions

working environment15-35 ℃, 10-85% RH; Storage environment: -10-50 ℃, 10-85% RH

Standard Appendix

AC adapter, battery charger, reset filter, power sampling head, portable protective box, operation manual, factory calibration report, Bluetooth printer, data export software

Optional accessories


Verification standards

JIS-B-9921(1997), ASTM-F649-01, ASTM-F328-98 (NIST 可溯源) JJG547-1988 GB/T6167-2007 JJF1190-2008

UCL Judgment Criteria

ISO14644 FS209E