GB/T 13277.1 Classification of Compressed Air Pollutants
Date: 2025-08-28Read: 9

GB/T 13277.1 Classification of Compressed Air Pollutants

compressed airMedium particle grade

The detection method should be based on the particle grade requirementsGB/T13277.4orISO8573-8Take measurements. When it is determined that there is a greater than5umWhen it comes to particles,Should not be used1Level up to5Level classification.

Particle grade

Maximum number of particles per cubic meter based on particle size a/m3


0.1 μm < d ≤ 0.5 μm

0.5 μm < d ≤ 1.0 μm

1.0 μm < d ≤ 5.0 μm

0

As specified by the device user or manufacturer (compared to the grade) 1 Higher requirements)


1

≤20000

≤400

≤10


2

≤400000

≤6000

≤100


3

Not regulated

≤90000

≤1000


4

Not regulated

Not regulated

≤10000


5

Not regulated

Not regulated

≤100000


6

—

0 < Cₚ≤ 5

7

5 < Cₚ≤ 10

X

Cₚ> 10

Humidity and liquid water level in compressed air

Testing Standard

According to the requirements of humidity and liquid water levelGB/T13277.3orISO 8573-9Take measurements.


level

Pressure dew point(℃)

Liquid water quality concentrationg/m3

0

As specified by the device user or manufacturer (compared to the grade) 1 Higher requirements)


1

≤-70


2

≤-40


3

≤-20


4

≤+3


5

≤+7


6

≤+10


7

—

Cw ≤ 5

8

0.5 < Cw ≤ 5

9

5< Cw ≤ 10

X

Cw>10

Total oil content grade in compressed air


Should be in accordance withGB/T13277.2Measure liquid oil and suspended oil. The total oil content grade is3Level4Level andXGrade time,Under standard conditions, the oil vapor content generally does not have a significant impact on the total oil content,Therefore,It can be determined whether to measure oil vapor based on the situation. If it is necessary to measure oil vapor,Should be in accordance withGB/T13277.5Take measurements.

level

Maximum concentration of total oil content(mg/m³)

0

As specified by the device user or manufacturer (compared to the grade) 1 Higher requirements)

1

≤0.01

2

≤0.1

3

≤1

4

≤5

X

>5

category judgment

General judgment

judgment criteria/data status

detection method

Determination of live microorganisms

Determine based on the usage environment of the clean room

No relevant judgment criteria or data available

GB/T 13277.7-2021[Current] Compressed air 第7Part: Methods for measuring the content of active microorganisms