Product Features
The TW-SC1000 sterile transfer chamber uses hydrogen peroxide vapor as a biological cleaning agent, which belongs to the cleaning process under low temperature and normal pressure, efficient and environmentally friendly. The hydrogen peroxide gas sterilization method is also included in the "sterilization method" in the pharmacopoeias of the United States, China and other countries
2. The operation of each stage of the equipment is automatically controlled by Siemens programmable logic controller (PLC), ensuring stable and reliable system operation
During the biological decontamination and exhaust stages, the air sent into the cabin is filtered through an H14 HEPA filter to prevent contamination of the materials
4. It has an independent ventilation and exhaust unit, including a fan, pneumatic butterfly valve, and exhaust pipeline, which can quickly replace hydrogen peroxide gas in the cabin and prevent it from entering the HAVC system
5. The incoming and outgoing materials adopt a double door structure, which has pneumatic sealing, pneumatic locking, and double door interlocking functions in working state
6. Internally equipped with a trolley type material support and its track system, convenient for material loading and unloading
7. The system has real-time monitoring functions for temperature, humidity, and pressure inside the cabin, and can be optionally equipped with ports for detecting hydrogen peroxide gas concentration, dust particles, and planktonic bacteria
8. Easy to verify, with complete IQ, OQ, PQ files, and able to provide on-site verification
9. It has the function of saving and printing biological decontamination cycle parameter data
Technical Specifications
Chamber material: SUS 304 stainless steel/SUS 316
High efficiency filter level: Supply HEPA: H14 level/Exhaust HEPA: H14 level
Alarm: High/Low Voltage Alarm; Open door timeout alarm; Lock door alarm
Biological decontamination cycle time:<90 minutes
Biological decontamination efficacy: lg ⁶ (thermophilic fat spore, ATCC12980 or ATCC7953)
VHPS residual level: ≤ 1ppm
Cabin cleanliness (particle level): Class A
Hydrogen peroxide gas decontamination circulation interface: DN32 sanitary interface
Exhaust interface: DN50 sanitary interface
Transmitting door diameter: 28cm
Dimensions: 150 × 105 × 180cm
Work area size: 100 × 100 × 100cm