Operating procedures for ultrasonic bottle washing machine
Date: 2025-03-20Read: 4
Ultrasonic bottle washing machine is a commonly used equipment in the pharmaceutical, chemical, food and other industries for cleaning bottles, especially pharmaceutical bottles. Proper operation and maintenance are of great significance for the effective use of equipment. Today, the editor will take you to understand the operating procedures of the ultrasonic bottle washing machine.
1、 Installation preparation
Before using the ultrasonic bottle washing machine, relevant installation preparations need to be carried out. as follows:
1. Confirm the placement of the bottle washing machine and ensure stability.
2. Check whether the power supply voltage and frequency meet the requirements. If they do not meet the requirements, electrical modification or replacement is needed.
3. Check the quality of the water source. If the water quality is poor, purification treatment is required.
4. Ensure that the working environment of the ultrasonic bottle washing machine is in good condition.
5. Connect the water inlet, drainage, power supply, and grounding wire.
二、操作方法
The operation method of ultrasonic bottle washing machine is as follows:
1. Turn on the main power switch.
2. Open the inlet and outlet valves to release the water inside the bottle washing machine, in order to achieve the purpose of cleaning the bottle washing machine.
3. Connect the ultrasonic bottle washing machine to the water source pipeline and adjust the inlet valve to ensure the normal operation of the equipment.
4. Turn on the motor switch and observe if the direction of rotation is correct. If it is not correct, the motor direction needs to be changed and re adjusted.
5. Adjust the temperature controller and set the water temperature to 40-50 ℃.
6. Put in the bottles that need to be cleaned and clean them according to the set time of the equipment.
7. After cleaning, close the inlet and outlet valves and drain the water inside the bottle washing machine.
8. Turn off the power switch to clean and maintain the equipment.
3、 Precautions
Attention should be paid to the following matters during use:
1. Ensure stable water pressure. Unstable water pressure may cause equipment damage or poor cleaning effectiveness.
2. Do not put your hands into the bottle washing machine during use to avoid accidental injury.
3. After the cleaning process is completed, the equipment needs to be thoroughly cleaned and maintained.