Common faults and troubleshooting methods of electric lubrication pump
| serial number | phenomenon | reason | Exclusion method |
| 1 | The motor is not running | The power supply voltage is incorrect | Input the required correct voltage |
| wrong connection | Connect the wires according to the electrical wiring diagram inside the pump cover | ||
| 2 | No oil output | Shou timesThe startup time is too short | Shou timesThe startup time should be at least 30 seconds |
| The air in the lubrication system has not been completely expelled | Using pre oil injection to fill the lubrication system with oil and exhaust the air in the lubrication system | ||
| 3 | The motor runs for 30 seconds without producing oil | Insufficient oil in the oil tank | Add clean lubricating oil to the oil tank to the height range indicated by the liquid level line |
| Blockage at the oil suction port | Check, clean or replace the oil filter screen at the suction port | ||
| 4 | Insufficient pressure | The pressure gauge is damaged and the indication is incorrect | Replace the qualified pressure gauge according to the pressure range requirements |
| Internal oil pipe detachment or leakage | Repair the detached oil pipe or apply sealant at the leakage site to treat the leak | ||
| 5 | Pressure switch out of control (SM-AC, SM-NC type programmable controllers) | Pressure switch damaged | Replace the pressure switch |
| The function settings on the program controller are incorrect | The number of cycles and timeout alarm function on the programmable controller must be set to a valid state | ||
| 6 | The indicator light is on, but the digits are not displayed or displayed incompletely (SM-AC, SM-NC type programmable controllers) | The connection between the display board plug and the computer board is loose | Insert the plug properly |
| The power supply does not meet the technical requirements | Check the power supply | ||
| There is serious interference on site | Eliminate sources of interference |