Date: 2021-05-10Read: 40

Mr. Wang from Jilin has completed the production of the DZSF-1840-3S linear vibrating screen ordered from our company. The equipment has passed the factory inspection and testing, and everything is running normally. It will be sent out to you through a dedicated line today and will arrive in about two days. Please prepare to receive the goods, Mr. Wang. Thank you for your trust and support in our company.

Installation, commissioning and use of linear vibrating screen:

The equipment should be fixed on a dedicated foundation and secured with pre embedded bolts. If a dedicated foundation is not built, anti vibration rubber plates should be laid between the workbench and the equipment base, and a safe and reliable grounding protection wire must be provided for the equipment before use.

Attention: After the equipment is installed in place, the device used to fix the screen body and machine base during transportation must be removed before starting up.

After the installation of the new screening machine, it should be inspected according to the following requirements:

1. Check the insulation resistance of the vibration motor winding to ground. If it is less than 20M Ω, it must be dried before use.

2. The springs on the upper and lower spring rings of the screen body and machine base should be vertically embedded in the spring rings to ensure the balance of the screen body. The vibrating parts of the screen machine should not have rigid connections or contact with other objects outside the machine.

3. Close the power switch, confirm that the vibration motor rotates synchronously in reverse, and perform 10-20 minutes of idle running. If there is any abnormal sound during the operation of the equipment, it should be quickly shut down for inspection and handling. After the equipment is running normally, a small amount of material that needs to be screened can be fed into the screening machine through the feeding port. Confirm that the material is moving towards the discharge port direction, and then gradually increase to the required and tolerable feeding amount.

4. When screening materials, the materials should be evenly fed into the inlet to ensure even distribution on the screening surface. When the material falls, there should be no significant impact to avoid damaging the sieve. In the following situations (such as large differences in material particle size, high material density, etc.), a thicker sieve should be added to the feed inlet as a buffer.

5. Users can adjust the excitation force of the screening machine based on the number of layers and the specific gravity of the material (by adjusting the angle between the eccentric weights at both ends of the vibration motor to increase or decrease the excitation force), in order to achieve a good screening effect.

6. When the equipment is shut down, it generates a momentary resonance zone, during which the amplitude and noise will significantly increase, which is a normal phenomenon. Before starting and stopping the equipment, there should be no residual material on the screen surface. The screen mesh should be checked regularly for tension and damage, and if there is any damage, it should be replaced immediately.