Date: 2023-04-24Read: 4
The DWJ-S3 experimental drip pill machine has a small volume, light weight, manual operation, digital display, automatic temperature control, and allows for arbitrary parameter settings. It works intuitively and is easy to operate. It can produce 5-70mg drop pills, which are very suitable for teaching demonstrations and new drug development in colleges and universities.
Instructions for using the DWJ-S3 experimental drip pill machine:
1. Firstly, connect the entire machine to the computer, connect the compressed air pipeline to the host, and adjust the pressure to 0.5MPa. Turn on the main control switch, and the lighting on the side of the drip head of the drip machine will light up. Indicates that the host power has been connected; At the same time, the touch screen automatically enters the operation screen.
2. Click on 'System Run' as needed.
3. After the system enters the "manual operation state", click on "parameter settings" to set various parameters, then click the "confirm" button and press the "return" button to return to the operation screen.
4. Click the "Heat" button and the "On/Off" button of the heating oil pump to enter the "Preheating State" of the system (this process will take approximately 1-2 hours). After reaching the set temperature, the system heating status will automatically turn off or manually shut down, stopping heating.
5. Click the "Pipe Heating" switch to bring the upper end of the cooling column to the set temperature.
6. Dripping: Click the "Auto" button in the menu. The automatic travel process is as follows: when the cooling and heating temperatures reach their set requirements, the system automatically starts stirring. When the set mixing time is reached, the system automatically opens the "feeding pipe valve" to add medication. After the drip tank is filled, the "feeding pipe valve" automatically closes. At the same time, manually turn on the "drip head" switch to start dripping, and synchronously automatically turn on the "conveyor belt" switch, at which point the equipment begins to operate. When the liquid level of the medicine drops to the lower limit of the "drip tank", the system opens the "feeding pipe valve" again to add medicine, and then automatically drips.
7. Cleaning: When the dispensing of the medicine is completed and no further dispensing is required, or when another type of medicine needs to be replaced, the "seasoning tank" and piping system need to be cleaned.