4112Aanderaa turbidity sensor

NegotiableUpdate on 04/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Aanderaa turbidity sensor 4112 is used for measuring turbidity in water. The sensor is designed to be integrated into the Andra Ocean Guardian platform, with an analog signal output of 0-5V. It has four range options, and one of them can be directly installed on the sensor disk at the top of the Ocean Guardian platform.

Product Details

Aanderaa turbidity sensor 4112

characteristic

Optical closed sensing volume

• Not sensitive to ambient light underwater

Linear output over 5 years

4 range options available

Optical feedback compensation for temperature drift and aging of optical components

Extremely low voltage drift, no need for adjustment

• Extremely low power consumption

application

• Pollution monitoring

Surface water and wastewater quality monitoring

• Sediment migration

• Ocean profile monitoring

• River and creek monitoring

Turbidity is measured by measuring the scattered light from water particles. Due to the good correlation between water turbidity and suspended solids concentration, monitoring of sediment, algae, and water particle pollution is usually carried out by measuring turbidity. The sensor output signal is a voltage signal, and the strength of this signal is proportional to the turbidity or suspended solids concentration of the water body.

It has extremely low power consumption, making it very suitable for applications with limited power supply. The drift of the sensor is between 0 and 1mV, and there is no need to adjust the gain. The unique optical design of the sensor enables it to measure sensitive areas within 5cm of the probe, making it suitable for measurements near the bottom and particularly suitable for applications that are heavily affected by reflection

The turbidity probe 4112 can be directly installed on the top sensor disk of the Ocean Guardian platform, and the sensor output is analog output. After connecting to the Ocean Guardian platform, the output data from the Ocean Guardian platform is engineering data.

Note: (1) The calibration range of the sensor standard is within the linear range of turbidity from 0-750NTU. If higher concentrations are required, please specify with the manufacturer when ordering.

(2) If there are any changes in the indicator parameters, no further notice will be given.