Welcome Customer !

Membership

Help

Shanghai Xuansheng Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products
Product Categories

Shanghai Xuansheng Scientific Instrument Co., Ltd

  • E-mail

  • Phone

    1502159571815121127657

  • Address

    No. 55 Huiyuan Road, Jiading Industrial Zone, Shanghai

Contact Now

Application of Liquid Chromatography in Pesticide Industry

NegotiableUpdate on 03/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Application of Liquid Chromatography in Pesticide Industry
Product Details
    Application of Liquid Chromatography in Pesticide Industry

    2-chloro-Nitroacetoacetanilide is an intermediate for the synthesis of pesticides such as quinoxaline, quinoxaline, and quinoxaline. This article uses high-performance liquid chromatography internal standard method to determine the content of p-chloro-o-nitroacetylacetamide. It achieves effective separation of p-chloro-o-nitroacetylacetamide and its impurities, with simple operation, fast results, good reproducibility, and accurate quantification.
    1、 Reagents and solutions
    Methanol: chromatographically pure, filtered through a 0.45um membrane before use;
    Water: Newly distilled secondary distilled water;
    Tetrahydrofuran: analytical grade;
    Imidacloprid: Impurity peaks without interference;
    Standard sample of chloroortho nitroacetylacetamide: known mass fraction>94.6%.
    2、 Instrument
    LC-3000 high-performance liquid chromatograph; Equipped with a variable wavelength ultraviolet detector;
    SW230 column temperature box;
    The anti control software for the all Chinese system includes a chromatography workstation;
    Chromatography column: C18 (150 mmx4.6mmx5um) stainless steel column;
    One hundred thousandth electronic balance;
    Ultra pure water system;
    Filter: The pore size of the filter membrane is about 0.45um.
    3、 Operating conditions for liquid chromatography
    Mobile phase: methanol+water=65+35 (v/v); Flow rate: 1.0mL/min; Column temperature: 30 ℃; Detection wavelength: 252nm; Injection volume: 5uL; Retention time: approximately 6min for 2-chloro-Nitroacetoacetanilide and 11.1min for pyrimethanil. The above liquid chromatography operating conditions are typical operating parameters. According to the characteristics of different instruments, appropriate adjustments can be made to the given operating parameters in order to achieve the best results.

    High performance liquid chromatograms of 2-chloro-Nitroacetoacetanilide and pyrimethanil.