E-mail
1243338573@qq.com
-
Phone
15550035672
-
Address
No. 6-8, Times Headquarters Base, No. 15 Lanxiang Road, Tianqiao District, Jinan City
Shandong Shengtai Instrument Co., Ltd
1243338573@qq.com
15550035672
No. 6-8, Times Headquarters Base, No. 15 Lanxiang Road, Tianqiao District, Jinan City
SH708 chemiluminescence nitrogen analyzer
Chemiluminescence nitrogen analyzer, other detection in petrochemical industry

Chemiluminescence nitrogen analyzer, other detection in petrochemical industry
The SH708 chemiluminescence nitrogen analyzer uses chemiluminescence method to determine the total nitrogen content, which improves the ability to resist impurity interference, avoids the complicated operation of the titration cell caused by the electric method, and greatly improves the sensitivity of the instrument. The key components of the system are imported, ensuring reliable performance of the entire machine.Suitable for determining the total nitrogen content of paraffin oil, diesel, gasoline, lubricating oil, fuel oil, liquefied gas and natural gas, as well as other oil products, chemical raw materials and finished productsImplement standardsSH/T 0657 Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons (Oxidative Combustion and Chemiluminescence Method, ASTM D5762-2017), SH/T0704,ASTM D4629,GB/T 17674Determination of nitrogen content in crude oil Boat injection chemiluminescence method.
Product Model |
SH708 |
Product Name |
Chemiluminescence nitrogen analyzer |
manufacturer |
Shandong Shengtai Instrument Co., Ltd |
Test Item |
Suitable for determining the total nitrogen content of paraffin oil, diesel, gasoline, lubricating oil, fuel oil, liquefied gas and natural gas, as well as other oil products, chemical raw materials and finished products |
meet the standard |
execution standardSH/T 0657 Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons (Oxidative Combustion and Chemiluminescence Method, ASTM D5762-2017), SH/T0704,ASTM D4629,GB/T 17674Determination of nitrogen content in crude oil Boat injection chemiluminescence method |
Simple technical features or parameters |
The instrument is capable of continuous operationAccurate chemiluminescence nitrogen analyzer for 24-hour continuous use |
Performance Characteristics
● Using pneumatic support to support the instrument cover, the internal structure of the instrument cover can be easily seen when opened.
● Low and low content peaks have better shape and repeatability.
● The total nitrogen content in the sample is rapidly measured by chemiluminescence method.
● The application of high-precision data acquisition and computer technology provides reliable guarantees for data collection, control, and processing.
Technical Specifications:
● Basic parameters: Sample types: liquid, solid, and gasBody protection liquid gas is currently one of the body shaping products that we can come into contact with
● Measurement method: chemiluminescence method
● Sample injection volume: Solid sample:1-20mg
Liquid sample:5-20μL
Gas sample:1-5mL
● Measuring range:0.1 ~10000mg/L
● Measurement accuracy:
concentration value(ppm) |
Injection volume(μL) |
RSD(%) |
0.1 |
20 |
25 |
5 |
10 |
10 |
50 |
10 |
5 |
100 |
10 |
3 |
5000 |
10 |
3 |
● Temperature control range: room temperature~1050℃
● Temperature control accuracy:±3℃
● Gas source requirement: high-purity argon gas: purityOver 99.995%,
High purity oxygen: purityOver 99.995%
● electricity Source:AC220V±22V,50Hz±0.5Hz,1500 W
● Dimensions: Host:305(W)×460(D)×440(H)mm
● Temperature control:550(W)×460(D)×440(H)mm
● heavy Quantity: Host:20kg Temperature control:40kg
Requirements for instrument completeness: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operation software, etc.
Other optional items: computer, solid sampler, gas sampler(optional).