Electromagnetic water meter is an electronic water meter that measures flow based on Faraday's law of electromagnetic induction. Widely used for measuring various types of water in the water industry, such as raw water, water supply, sewage treatment, and water conservancy engineering industries.
Product Features
1. There are no movable parts or flow blocking parts in the table, and there is almost no additional pressure loss during measurement.
2use16The embedded low-power processor is specially designed with sensor excitation circuit and high-efficiency lithium battery power management system, which has the characteristics of fully digital signal processing, stable measurement, high measurement accuracy, and strong anti-interference ability.
3. Automatic bidirectional flow measurement, on-site instantaneous flow, cumulative total display in both directions, and self diagnostic fault alarm.
4. Built in battery power supply, no external power supply is required on site.
5. Accurate measurement, high reliability, good stability, and long service life.
6. Integrated modular assembly design, on-site component replacement plug-in design, no need for welding and secondary sealing.
7The monitor adopts low power consumptionLCDThe large screen LCD display can display multiple flow parameters such as instantaneous flow rate, flow velocity, pressure, cumulative total amount in both directions, and alarm prompts.
8. Provide self diagnostic function, dedicated infrared remote control operation, no need for button operation.
9Integrated design of measurement and transmission, which can be achieved throughRS485perhapsGPRSInterface implementation for remote data transmission
10. External pressure sensors can be used to measure and monitor pipeline pressure.
Technical Parameter
|
Nominal diameter |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
|
Common traffic(Q3)m³/h |
100 |
100 |
160 |
250 |
400 |
630 |
100 |
1600 |
1600 |
|
Range ratio(Q3/Q1) |
400 |
||||||||
|
Q2/Q1 |
1.6 |
||||||||
|
accuracy class |
2level |
||||||||
|
Pressure loss level |
△p25 |
||||||||