FKTA23-NW01 Load Management Terminal

NegotiableUpdate on 04/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Main features: The load management terminal strictly complies with the Technical Specification for Load Management Terminals of China Southern Power Grid Co., Ltd. It is a new generation of power monitoring terminal based on an embedded software and hardware development platform, with high integration and advanced technology. It adopts communication methods such as 4G GPRS/CDMA/GSM/SMS/audio telephone, and is widely used in on-site power service and management systems and load management systems. It provides reliable technical means for customer service, power inspection, orderly power consumption, off peak power consumption, safe power consumption, and alleviates power shortages. It is a product with high performance price ratio.
Product Details

Technical parameters:

Normal operating temperature

-25 ℃~+55 ℃ (recommended)

working temperature limit

-40℃~+80℃

humidity

Relative humidity ≤ 100%;

atmospheric pressure

63.0kPa~108.0kPa (altitude 4000m and below)

Working power supply

Rated voltage 220V ± 30%, frequency 50HZ ± 6%

Frequency range

50Hz, allowable deviation-6%~+2

External dimensions

Width x Length x Height=112mm x 160mm x 71mm

display

LED indicator light

interface type

3 RS485 channels (1 for RS485 maintenance, 2 for meter reading, maintenance port can be set as meter reading), 1 USB, 1 modulated infrared, 1 remote communication interface

Voltage

Three phase four wire, 1.0 level; 3×220/380V

Current specifications

3 × 1 (2) A, 3 × 5 (10) A

Frequency range

50Hz, allowable deviation-6%~+2

External dimensions

Width x Height x Thickness=180mm x 290mm x 95mm

Meter reading and interface settings

3-channel RS485 interface (lightning protection), 2-channel meter reading, 1-channel maintenance;

Local settings interface

1 infrared/TTL, 1 RS-232 interface;

pulse output

2 channels, with 1 active and 1 reactive;

Clock output

1 Road

Remote signaling input

4 routes, DC12V

Door contact input circuit

1 route, DC12V

Switching output circuit

4-channel, AC250V/5A DC30V/5A normally open, normally closed, non self holding output

ALARM IN

1 channel, AC250V/5A DC30V/5A normally open, non self holding output

Communication sampling circuit

1 group, three-phase three wire/three-phase four wire

insulation voltage

2000V

AC sampling

Active power level 1.0, reactive power level 2.0