Feed analysis liquid chromatography instrument

NegotiableUpdate on 03/31
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The use of feed analysis liquid chromatography in the detection of feed and feed additives: determination of vitamin A B1 B2 B3 B6 B12 E D K3, liquid chromatography of niacin and folic acid (feed type)
Product Details

Feed analysis liquid chromatography instrument

Material analysis liquid chromatography instrumentPurpose:

Determination of Vitamin A B1 B2 B3 B6 B12 E D K3, Niacin, Folic Acid, etc

Product Name

Specification and model

Company

quantity

amount of money

Place of Origin

High pressure constant flow pump

PT501

platform

1

Hangzhou

UV detector

UV501

platform

1

Hangzhou

Manual injection valve

8725i

only

1

Hangzhou

Chromatography workstation

N2000 (liquid phase specific)

set

1

Hangzhou

Liquid chromatography column

C18 4.6×250mm,5um

branch

1

VERTEX

Microsampler

50ul/100ul

branch

1

Shanghai

Injection bracket

For injection valve

only

1

Column temperature box

DT230A

platform

1

Dalian

Vacuum pump

AP-01P (with pressure gauge)

platform

1

Tianjin

Solvent filter

1000ml

platform

1

Jiangsu

Ultrasonic degassing machine

SZ-80(2L)

platform

1

Tianjin

Water based microporous filter

Φ 13 × 0.45 (100 pieces/pack)

package

1

Tianjin

Organic microporous filter

Φ 13 × 0.45 (100 pieces/pack)

package

1

Tianjin

Water based microporous filter membrane

Φ 50 × 0.45 (50 pieces/box)

box

1

Tianjin

Organic microporous membrane

Φ 50 × 0.45 (50 pieces/box)

box

1

Tianjin

Note: Customers are requested to bring their own pre-treatment equipment for feed samples. (The configuration may vary slightly according to customer needs)

LC01 typeFeed analysis liquid chromatography instrumentIt is a liquid chromatography instrument developed, designed, processed, and produced by the company based on customer needs and utilizing foreign resources. The automatic cleaning device for the plunger rod is easy to operate and reduces the cost of using the plunger rod; The designed "floating double plunger rod and sealing ring" can cover the service life and cost of the sealing ring; Self suction one-way valve, the world's largest one-way valve and adjustable solvent compression factor, ensures stable pump flow and has become one of the pumps with external pressure fluctuations (pressure fluctuations far less than 10Psi or 0.5kg/fom). The STI501 isocratic liquid chromatograph can be used as a gradient pump, with excellent characteristics such as stable quality, performance, and cost-effectiveness. It can be applied in research and development, pharmaceutical inspection, food testing, chemical analysis, environmental monitoring and other analytical fields.

The main characteristics of

Characteristics of PT01 high-pressure constant current infusion pump
The infusion pump performs self inspection upon startup, automatically identifies faults, and has built-in high and low pressure alarm and protection functions;
The self-priming one-way valve designed can seal the service life of the ring;
By controlling the closure of external contacts, it is easy to change the purpose of the pump;
The pump head components are designed separately for easy disassembly and maintenance;
The pump head has a self flushing function, and the pump manually empties the infusion solution;
Automatically detect pump head type and adjust parameter settings;
Complete pre cleaning function;
Pump types: analytical, semi prepared, and prepared;
Programmed solvent compression factor that can automatically compensate for flow rate;
The components are easy to maintain and repair;
Gradient elution software can self control, edit, and store 60 gradient methods, and run complex gradient programs;
The pump parameters can be controlled by both the pump panel and the system controller under different requirements, making it convenient and flexible.

Characteristics of UV01 UV detector
Power on self-test, the instrument has alarm and automatic fault diagnosis functions;
The optical path system adopts a precise positioning structure and heat dissipation, as well as an optical system and digital filtering;
Light source: optional deuterium lamp and tungsten lamp, deuterium lamp warranty life of 1000Hrs;
Original light source, without adjusting the optical axis during light source operation, easy to maintain;
Real time display of sample pool and reference pool, facilitating the determination of the status of light source and flow pool;
Online monitoring and display of the running time of the light source, facilitating the lifespan of the light source for users;
High brightness OLED display screen, stable and beautiful;
Multi range output selection for various concentration analysis requirements;
Zeroing function: The absorbance can be zeroed by the panel or automatically zeroed by the program software;
Wavelength adjustment function: It can be controlled by the keyboard panel or set by program software. It is a fully enclosed integrated photoelectric detection element, and the mechanical part adjusts the selection or changes of wavelength;
Equipped with micro, semi prepared, and prepared detection pools, easy to convert;
The instrument has good universality and can be applied in different fields of scientific research.

The indicators

PT501 high-pressure constant current infusion pump

Infusion method

Micro volume series double plunger

Flow range

(0.001~10.000)mL/min, Incremental 0.001mL/min (analytical type).

Flow accuracy

0.1%

Traffic accuracy

<±1 % (2μl/min)

Conveying pressure

6000Psi (approximately 42MPa)

Solvent compressibility

Automatic compensation

nature

Equipped with power on self-test, high and low voltage alarm and protection functions

size

W260×H170×D360mm

Net weight

6.3kg

UV501 UV Variable Wavelength Detector

light source

Deuterium lamp (tungsten lamp optional)

Wavelength Range

190-700nm (step up by 1nm), can be set by keyboard or RS-232.

Wavelength accuracy

<±1nm

Wavelength reproducibility

<±0.5nm

bandwidth

Less than 5nm

noise

<± 2.5 × 10-5AU (under specific conditions)

drift

<± 2.5 × 10-4AU (under specific conditions)

Flow pool volume

10ul

Absorption range

0.01AU/V to 10AU/V (ten levels in total)

size

W260×H170×D360mm

weight

6.0kg