Welcome Customer !

Membership

Help

Heyuan Intelligent Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Heyuan Intelligent Technology Co., Ltd

  • E-mail

    hy_dzswwx@163.com

  • Phone

  • Address

    7th Floor, Building 1, Aosheng Building, No. 1166 Xinluo Street, High tech Zone, Jinan City, Shandong Province

Contact Now

Fire equipment power status monitor

NegotiableUpdate on 05/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HYFP-B electrical fire monitoring equipment is wall mounted and can monitor up to 800 points. As the core of the fire equipment power monitoring system, it adopts strict design, selects reliable and stable microcontrollers, and works together with voltage signal sensors and voltage/current signal sensors.

Product Details

Technical Parameter

Detection object

Single phase voltage/current, three-phase voltage/current

working voltage

AC220V±15%/50HZ

power consumption

15W (excluding sensors and supporting equipment)

Communication method

Two bus communication

Optional specifications

64.128.200.400.600.800

Alarm method

audible and visual alarm

ALARM IN

Built in three sets of programmable external control outputs, with contact capacities of 2A/DC24V or 1A/AC220V

Spare battery

12V/7Ah lead-acid battery×2

Display mode

7-inch 800 * 480 true color screen display

Distance

1500M(NH-RVS×1.5MM2

Printing function

Equipped with a micro thermal printer for Chinese character printing

Installation method

Wall Mount

External dimensions

410mm * 115mm * 540mm (length * width * height)


Functional advantages

The system features a non-polar dual bus design to prevent equipment damage caused by wiring errors;

The signal power supply shares two wires to reduce wiring costs;

Built in large capacity data storage, which can classify and store on/off records, fault records, power interruption records, and other event records. It can still be saved even in the event of a power outage;

7-inch color screen LCD Chinese display, more convenient to operate;

Extra large load capacity, no need to install extension units;

Reliable power supply and communication over a long distance of 1500m, meeting the design needs of various projects.

Model Selection Table

Equipment name

Equipment model

specifications

describe

Fire equipment power monitor

HYFP-B

64 point position

Note: The monitoring point is the data point, which is the sum of the detection channels of the voltage sensor and the voltage/current sensor.

128 point position

200 points

400 points

600 points

800 points