Fully automatic aluminum-plastic packaging machinePerformance Characteristics
1. Adopting a new domestic high-power transmission mechanism, the main transmission shaft is driven by a chain, eliminating errors and noise from other gear transmissions.
2. By adopting an imported control system for electrical appliances, it is possible to configure missing materials and missing particles detection and removal devices according to customer requirements.
3. The whole machine adopts segmented combination: PVC forming, feeding, and heat sealing are in one section, and tropical aluminum cold forming, heat sealing, and punching are in one section for separate packaging.
4. Using a photoelectric control system, PVC、PTP、 The automatic feeding and waste edge cutting device for hard aluminum packaging ensures the synchronous stability of multiple workstations over long distances.
5. It can be equipped with a photoelectric detection and calibration device, imported stepper motor traction, graphic and text printing packaging, and optimized packaging grade.
6. This machine is suitable for: capsules, tablets, sugar coating, capsules, injections, irregular shapes, as well as medical devices, light food, electronic components bubble sealed packaging.
Technical Specifications
| model | DPB-80 |
| Punching frequency | 10-40 times/minute |
| production capacity | 2400 version/hour |
| Maximum molding area and depth | 80 * 110 * 26 millimeters (mm) |
| Standard itinerary range | 20-70 millimeters (can be designed according to customer requirements) |
| Standard section | 80 * 57mm (can be designed according to customer requirements) |
| air pressure | 0.6-0.8 megapascals |
| Total power of the power supply | 380V/220V 50Hz 3.2Kw |
| Main electrode power | 0.75Kw |
| PVC rigid sheet | 0.15-0.5 * 80 millimeters (mm) |
| PTP铝箔 | 0.02-0.035 * 80 millimeters (mm) |
| Dialysis paper | 50-100g * 80mm (mm) |
| Mold cooling | Tap water or circulating water |
| Overall dimensions | 1600 * 600 * 1100 millimeters (mm) |
| Weight | 450 kilograms (Kg) |
| Noise index | <75dBA |
workflow
1. Forming (heating up and down)
2. Heat sealing (upper heating)
3. Code it
4. Indentation (with trace heating)
5. Cutting knife
6. Forming and outputting finished products
sample image

Configuration List
Moving parts
| serial number | name | quantity | model | Place of Origin |
| 1 | Traction transmission cylinder | 2 | φ 32 × stroke 15 | Ruian Yida |
| 2 | main motor | 1 | YS750W-4R | Wenzhou Dongli |
| 3 | Heating area | 3 | AL100×130 | Taixing, Jiangsu |
| 4 | frequency converter | 1 | DVA-2S0007G | Easy to drive |
| 5 | feeding motor | 1 | 31K15GN-C | Wenzhou Dongli |
electrical components
| serial number | name | quantity | model | Place of Origin |
| 1 | thermocouple | 2 | LI-2M | Zhejiang Zhongpu |
| 2 | air circuit breaker | 1 | DZ47-63/10A | Zhejiang Chint |
| 3 | air circuit breaker | 2 | DZ47-63/6A | Zhejiang Chint |
| 4 | air circuit breaker | 1 | DZ47-63/25A | Zhejiang Chint |
| 5 | relay | 5 | HRS4H-S | Hong Kong HKE |
| 6 | microcontroller | 1 | panel | Sino-foreign joint venture |
| 7 | Solid state relay motor | 2 | SSR-40DA | Yangming, Taiwan, China, China |
| 8 | Control Transformer | 1 | JBK3-63 | Zhejiang Chint |
| 9 | solenoid valve | 1 | SG4V210-08 | Wenzhou Yida |
| 10 | Emergency stop button | 1 | LAY2 | Zhejiang Chint |

Fully automatic aluminum-plastic packaging machineOperation instructions
Before operation, carefully read the equipment manual to understand its performance, structure, operating methods, and precautions.
Check if the equipment is in good condition, if all components are functioning properly, and if the power cord is securely connected.
Choose the appropriate mold based on the shape and size of the packaged item. Install the mold onto the equipment and adjust its position.
Turn on the power switch of the device, set the packaging parameters (such as packaging speed, sealing temperature, etc.), and then press the start button to start the device.
During the operation of the equipment, the working status of the equipment should be observed at all times, and if there are any abnormal situations, the machine should be stopped immediately for handling.
After the equipment completes a packaging task, any residue inside the equipment should be promptly cleaned to maintain its cleanliness.
When the device is not in use for a long time, the power switch should be turned off, the power plug should be unplugged, and the device should be stored in a dry, cool place.
Maintenance Notice
Regularly inspect the various components of the equipment, such as chains, bearings, gears, etc., and replace them promptly if wear or damage is found.
Inspect the electrical components of the equipment, such as wires, sockets, switches, etc., to ensure that they are intact and undamaged.
Inspect the heating components of the equipment, such as heating plates and thermocouples, to ensure their proper functioning.
Inspect the transmission components of the equipment, such as chains, gears, etc., to ensure they are smooth and unobstructed.
Check the control system of the equipment, such as touch screen, PLC, etc., to ensure its normal operation.
Inspect the pneumatic components of the equipment, such as cylinders and valves, to ensure their proper functioning.
Inspect the hydraulic components of the equipment, such as oil cylinders, oil pumps, etc., to ensure their normal operation.
Check the lubrication system of the equipment, such as lubricating oil, grease, etc., to ensure that it is sufficient and of good quality.
Inspect the safety protection devices of the equipment, such as protective covers, safety doors, etc., to ensure their integrity and reliability.
Regularly maintain the equipment, such as cleaning, lubrication, fastening, etc., to ensure its normal operation.
Precautions
When operating, the requirements of the equipment manual should be followed, and unauthorized operation is strictly prohibited.
When maintaining equipment, the power should be disconnected first to ensure that the equipment is in a shutdown state. At the same time, protective equipment such as gloves and masks should be worn to prevent accidental injuries.
When replacing vulnerable parts of equipment, reliable products should be selected to ensure the normal operation of the equipment.
When the equipment malfunctions, it is necessary to promptly contact the equipment manufacturer or professional maintenance personnel for handling, and do not disassemble and repair it on your own.
During the operation of the equipment, attention should be paid to observing the operating status of the equipment. If there are any abnormal situations, the machine should be stopped immediately for handling.