G2106 gas concentration analyzer measures C2H4

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Measure C2H4
Product Details

The Picarro G2106 gas concentration analyzer can accurately measure ethylene (C2H4) and water vapor (H2O) in real-time, with a sensitivity of parts per billion (ppb), and the drift generated for agricultural and soil science applications can be ignored. This analyzer requires almost no consumables, therefore it has significant advantages of ease of use and lower purchase cost. This analyzer has a sturdy structure and is easy to transport. This analyzer can be set up and put into operation within a few minutes, and usually does not require any sample preparation or drying treatment.

  • Fast, continuous, real-time measurement of C2H4

  • Long term stability to meet low-frequency calibration requirements

  • Small footprint, suitable for on-site or laboratory deployment, no need for consumables

  • Equipped with water vapor correction function, automatically reporting dry gas mole fraction

The accuracy at 5 seconds and 5 minutes is 2 ppb and 0.2 ppb, respectively. The drift within 24 hours at standard temperature and pressure (STP) is less than ± 0.4 ppb. The moisture correction software will automatically report the dry gas mole fraction to help reduce the complexity of research work and save consumable costs.


Picarro G2106 Performance Specifications
Target gas (requires air like background) Detection lower limit*(5 seconds/5 minutes, 1 σ)
*Ensure that the following operating conditions are met
Maximum drift*(Within 24 hours/month) (The difference between the 50 minute average and the maximum value)
*Ensure that the following operating conditions are met
C2H4 2 ppb / 0.2 ppb < ±4='' ±10=''>
Picarro G2106 System Specifications
measurement Cavity ring down spectroscopy (CRDS) technology
Measurement pool temperature control ±0.005 ℃
Measurement pool pressure control ± 0.0002 atmospheric pressure
measuring range 0–300 ppm
Measurement Interval About 5 seconds
sample temperature -10 to 45 ℃
Sample flow rate Less than 0.4 standard liters per minute (SLM) at 760 pallets, no filtration required
Sample pressure 300 to 1000 Torr (40 to 133 kPa)
Sample humidity Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃
ambient temperature 10 to 35 ℃ (during operation), -10 to 50 ℃ (during storage)
ambient humidity Under non condensing conditions, the relative humidity (RH) is less than 99%
Other gases measured H2O
attachment Pump (external, included), keyboard (included), mouse (included), LCD monitor (optional)
data output RS-232、 Ethernet USB、 Analog signal (optional) 0-10 volts
Air inlet connector ¼ inch Swagelok ® PFA connector
External dimensions Including the legs, it measures 17 inches wide x 7 inches high x 17.5 inches long (43.2 x 17.9 x 44.5 centimeters),
The small external pump module measures 5.6 inches wide x 6.4 inches high x 11.9 inches long (14.3 x 16.3 x 30.3 centimeters)
Installation form Workbench or 19 inch rack mounted chassis
weight Analyzer weighs 46 pounds (20.9 kilograms), pump weighs 14.4 pounds (6.5 kilograms) (excluding connectors)
Power requirements 100-240 volts AC, 47-63 Hz (automatic detection), total power at startup less than 260 watts
At steady state, it is 110 watts (analyzer) and 80 watts (pump)
Application precautions We need an air like background. When the concentrations of H2O, CO2, and CH4 are much higher than normal environmental levels, as well as when measuring organic compounds including but not limited to ethane, acetylene, ammonia, and other nitrogen and sulfur containing compounds, interference may occur. Users should use prepared laboratory samples for validation. For more details about the experimental conditions, please contact us. When the system is used in recycling applications, the pressure difference in the instrument air path may draw in external air.