The Picarro G2106 gas concentration analyzer can accurately measure ethylene (C2H4) and water vapor (H2O) in real-time, with a sensitivity of parts per billion (ppb), and the drift generated for agricultural and soil science applications can be ignored. This analyzer requires almost no consumables, therefore it has significant advantages of ease of use and lower purchase cost. This analyzer has a sturdy structure and is easy to transport. This analyzer can be set up and put into operation within a few minutes, and usually does not require any sample preparation or drying treatment.
Fast, continuous, real-time measurement of C2H4
Long term stability to meet low-frequency calibration requirements
Small footprint, suitable for on-site or laboratory deployment, no need for consumables
Equipped with water vapor correction function, automatically reporting dry gas mole fraction
The accuracy at 5 seconds and 5 minutes is 2 ppb and 0.2 ppb, respectively. The drift within 24 hours at standard temperature and pressure (STP) is less than ± 0.4 ppb. The moisture correction software will automatically report the dry gas mole fraction to help reduce the complexity of research work and save consumable costs.
| Picarro G2106 Performance Specifications | ||
| Target gas (requires air like background) |
Detection lower limit*(5 seconds/5 minutes, 1 σ) *Ensure that the following operating conditions are met |
Maximum drift*(Within 24 hours/month) (The difference between the 50 minute average and the maximum value) *Ensure that the following operating conditions are met |
| C2H4 | 2 ppb / 0.2 ppb | < ±4='' ±10=''> |
| Picarro G2106 System Specifications | ||
| measurement | Cavity ring down spectroscopy (CRDS) technology | |
| Measurement pool temperature control | ±0.005 ℃ | |
| Measurement pool pressure control | ± 0.0002 atmospheric pressure | |
| measuring range | 0–300 ppm | |
| Measurement Interval | About 5 seconds | |
| sample temperature | -10 to 45 ℃ | |
| Sample flow rate | Less than 0.4 standard liters per minute (SLM) at 760 pallets, no filtration required | |
| Sample pressure | 300 to 1000 Torr (40 to 133 kPa) | |
| Sample humidity | Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃ | |
| ambient temperature | 10 to 35 ℃ (during operation), -10 to 50 ℃ (during storage) | |
| ambient humidity | Under non condensing conditions, the relative humidity (RH) is less than 99% | |
| Other gases measured | H2O | |
| attachment | Pump (external, included), keyboard (included), mouse (included), LCD monitor (optional) | |
| data output | RS-232、 Ethernet USB、 Analog signal (optional) 0-10 volts | |
| Air inlet connector | ¼ inch Swagelok ® PFA connector | |
| External dimensions | Including the legs, it measures 17 inches wide x 7 inches high x 17.5 inches long (43.2 x 17.9 x 44.5 centimeters), The small external pump module measures 5.6 inches wide x 6.4 inches high x 11.9 inches long (14.3 x 16.3 x 30.3 centimeters) |
|
| Installation form | Workbench or 19 inch rack mounted chassis | |
| weight | Analyzer weighs 46 pounds (20.9 kilograms), pump weighs 14.4 pounds (6.5 kilograms) (excluding connectors) | |
| Power requirements | 100-240 volts AC, 47-63 Hz (automatic detection), total power at startup less than 260 watts At steady state, it is 110 watts (analyzer) and 80 watts (pump) |
|
| Application precautions | We need an air like background. When the concentrations of H2O, CO2, and CH4 are much higher than normal environmental levels, as well as when measuring organic compounds including but not limited to ethane, acetylene, ammonia, and other nitrogen and sulfur containing compounds, interference may occur. Users should use prepared laboratory samples for validation. For more details about the experimental conditions, please contact us. When the system is used in recycling applications, the pressure difference in the instrument air path may draw in external air. | |