The Picarro G2108 gas concentration analyzer can accurately measure hydrogen chloride (HCl) and water vapor (H2O) in real-time, with a sensitivity of parts per trillion (ppt), and the drift generated for atmospheric science and air quality applications can be ignored. This analyzer reduces the tendency of HCl molecules to adhere to the surface of the gas pathway, thereby improving the measurement response time. This analyzer requires almost no consumables, therefore it has significant advantages of ease of use and lower purchase cost. This analyzer has a sturdy structure and is easy to transport.
Fast, continuous, and real-time measurement of HCl
Long term stability to meet low-frequency calibration requirements
Small footprint, suitable for on-site or laboratory deployment, no need for consumables
Equipped with water vapor correction function, automatically reporting dry gas mole fraction
The accuracy at 5 minutes is less than 120 ppt. The drift within 24 hours at standard temperature and pressure (STP) is ± 400 ppt. The moisture correction software will automatically report the dry gas mole fraction to help reduce the complexity of research work and save consumable costs.
| Picarro G2108 Performance Specifications | HCl | H2O |
| Accuracy (1 σ, 10 seconds/30 seconds/300 seconds) | 45 ppt / 30 ppt / 10 ppt | 20 ppm+8 * H2O [%] (10 seconds) |
| Detection limit (300 seconds, 3)σ) | ≤ 30 ppt | ≤ 20 ppm |
| Zero drift (within 24 hours/1 month) | ± 50 ppt / ± 250 ppt | ±40 ppm / ±200 ppm |
| measuring range | 0–1000 ppb | 0–40000 ppm |
| Measurement Interval | < 5=''> | < 5=''> |
| response time | 0–1 ppm: Descent time (90-10%):<1=''> Rise time (10-90%):<1=''> |
0–10000 ppm: Descent time (90-10%):<20=''> Rise time (10-90%):<20=''> |
| Picarro G2108 System Specifications | ||
| measurement | Cavity ring down spectroscopy (CRDS) technology | |
| Measurement pool temperature control | ± 0.005 ℃ | |
| Measurement pool pressure control | ± 0.0002 atmospheric pressure | |
| sample temperature | -10 to 45 ℃ | |
| Sample flow rate | <1.8='' Standard liters per minute='' (='' slm=''> | |
| Sample pressure | 600 to 850 Torr (80 to 113 kPa) | |
| Sample humidity | Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃ | |
| ambient temperature | 15 to 35 ℃ (during operation); -10 to 50 ℃ (during storage) | |
| ambient humidity | Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃ | |
| Other gases measured | CH4 | |
| attachment | Pump (external, included), keyboard and mouse (included), LCD monitor (optional) | |
| data interface | RS–232、 Ethernet USB | |
| Air inlet connector | ¼ inch Swagelok ® | |
| External dimensions | Analyzer: 17 inches wide x 7 inches high x 17.5 inches long (43.2 x 17.9 x 44.6 centimeters), excluding 0.5 inch feet External pump: 12.8 inches long x 8.9 inches high x 6.2 inches wide (32.4 x 22.6 x 15.8 centimeters) |
|
| weight | 73 pounds (33.18 kilograms), including pump | |