G2108 gas concentration analyzer measures HCl

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Measure HCl
Product Details

The Picarro G2108 gas concentration analyzer can accurately measure hydrogen chloride (HCl) and water vapor (H2O) in real-time, with a sensitivity of parts per trillion (ppt), and the drift generated for atmospheric science and air quality applications can be ignored. This analyzer reduces the tendency of HCl molecules to adhere to the surface of the gas pathway, thereby improving the measurement response time. This analyzer requires almost no consumables, therefore it has significant advantages of ease of use and lower purchase cost. This analyzer has a sturdy structure and is easy to transport.

  • Fast, continuous, and real-time measurement of HCl

  • Long term stability to meet low-frequency calibration requirements

  • Small footprint, suitable for on-site or laboratory deployment, no need for consumables

  • Equipped with water vapor correction function, automatically reporting dry gas mole fraction

The accuracy at 5 minutes is less than 120 ppt. The drift within 24 hours at standard temperature and pressure (STP) is ± 400 ppt. The moisture correction software will automatically report the dry gas mole fraction to help reduce the complexity of research work and save consumable costs.


Picarro G2108 Performance Specifications HCl H2O
Accuracy (1 σ, 10 seconds/30 seconds/300 seconds) 45 ppt / 30 ppt / 10 ppt 20 ppm+8 * H2O [%] (10 seconds)
Detection limit (300 seconds, 3)σ ≤ 30 ppt ≤ 20 ppm
Zero drift (within 24 hours/1 month) ± 50 ppt / ± 250 ppt ±40 ppm / ±200 ppm
measuring range 0–1000 ppb 0–40000 ppm
Measurement Interval < 5=''> < 5=''>
response time 0–1 ppm:
Descent time (90-10%):<1=''>
Rise time (10-90%):<1=''>
0–10000 ppm:
Descent time (90-10%):<20=''>
Rise time (10-90%):<20=''>
Picarro G2108 System Specifications
measurement Cavity ring down spectroscopy (CRDS) technology
Measurement pool temperature control ± 0.005 ℃
Measurement pool pressure control ± 0.0002 atmospheric pressure
sample temperature -10 to 45 ℃
Sample flow rate <1.8='' Standard liters per minute='' (='' slm=''>
Sample pressure 600 to 850 Torr (80 to 113 kPa)
Sample humidity Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃
ambient temperature 15 to 35 ℃ (during operation); -10 to 50 ℃ (during storage)
ambient humidity Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ℃
Other gases measured CH4
attachment Pump (external, included), keyboard and mouse (included), LCD monitor (optional)
data interface RS–232、 Ethernet USB
Air inlet connector ¼ inch Swagelok ®
External dimensions Analyzer: 17 inches wide x 7 inches high x 17.5 inches long (43.2 x 17.9 x 44.6 centimeters), excluding 0.5 inch feet
External pump: 12.8 inches long x 8.9 inches high x 6.2 inches wide (32.4 x 22.6 x 15.8 centimeters)
weight 73 pounds (33.18 kilograms), including pump