G2301 gas concentration analyzer measures CO2, CH4, and H2O

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Measure CO2, CH4, and H2O
Product Details

The Picarro G2301 gas concentration analyzer can accurately measure carbon dioxide (CO2), methane (CH4) with a sensitivity of parts per billion (ppb), and water vapor (H2O) with a sensitivity of parts per million (ppm) simultaneously. The drift generated for atmospheric science, air quality, and quantitative emission applications can be ignored. This analyzer meets the performance requirements of the World Meteorological Organization (WMO) and the Integrated Carbon Observing System (ICOS) for atmospheric monitoring of CO2 and CH4.


  • Simultaneous and continuous measurement of three atmospheric trace gases

  • Billion parts per billion (ppb) sensitivity, accuracy, and precision, with extremely low drift

  • Complies with the international environmental and atmospheric monitoring requirements of WMO and ICOS

  • Equipped with water vapor correction function, automatically reporting dry gas mole fraction


For CO2, the accuracies at 5 seconds and 5 minutes are<70 ppb='' and=''>70><25 ppb, respectively. For CH4, the accuracies are=''>25><0.5 ppb='' and=''>0.5><0.22 ppb, respectively. For='' CO2 and='' CH4, the maximum drift within 24 hours at standard temperature and pressure='' (STP)='' is='>0.22><120 ppb=' 'and='>120><1>, respectively

Picarro G2301 ensures performance specifications (in air) CO2 CH4 H2O
Accuracy (1 σ)
Ensure accuracy under the following specified operating conditions
5 seconds < 70=''>
Typical value=15 ppb*
< 0.5=''>
Typical value=0.14 ppb*
< 80=''>
5 minutes < 25=''>
Typical value=5 ppb*
< 0.22=''>
Typical value=0.04 ppb*
< 30=''>
Maximum drift under standard temperature and pressure
***(The difference between the maximum values of the 50 minute average)
Ensure drift under the following specified operating conditions
24 hours 120 ppb
Typical value=17.0 ppb*
1 ppb
Typical value=0.10 ppb*
<>
monthly 500 ppb 3 ppb -
Automatic determination of dry mole fraction Already included Already included -
measuring range 0–1000 ppm 0–20 ppm 0-7% v (dew point at 39 ℃)
Under non condensing conditions
Ensure accuracy range 300–700 ppm 1–3 ppm 0-3% v (dew point at 25 ℃)
Under non condensing conditions
Measurement interval (data acquisition rate) < 5=''>
Typical value=2.8 seconds*
Gas response: rise/fall time (10-90%/90-10%) < 3=''>

**The typical performance is defined as the median of the test results of 36 G2301 analyzers manufactured in sequence. Results can be requested.

*Picarro calculates drift by subtracting the minimum value from the maximum value of the 50 minute average data obtained from a 30 hour experiment.


Picarro G2301 ensures operating conditions
measurement Cavity ring down spectroscopy (CRDS) technology
Measurement pool temperature control ±0.005 ℃
Measurement pool pressure control ± 0.0002 atmospheric pressure
sample temperature -10 to 45 ℃
Sample pressure 300 to 1000 Torr (40 to 133 kPa)
Sample flow rate <0.4 standard liters per minute='' (='' slm=''), at='' 760=''>0.4>
Sample humidity <99% relative humidity (at='' 40='' ℃=''>99%)
ambient temperature 10 to 35 ℃ (during instrument operation), -10 to 50 ℃ (instrument storage conditions)
ambient humidity <85%>85%>
Accessories (included) External vacuum pump, vacuum pipeline and accessories, keyboard, mouse, LCD display (optional), built-in 240GB hard drive
data output RS-232, Ethernet, USB, Analog signal (optional) 0-10 volts
Air inlet connector ¼ inch Swagelok ®
size Analyzer: 17 inches wide x 7 inches high x 17.5 inches deep (43.2x17.8x44.5 centimeters), excluding 0.5 inch foot pads
External pump: 7.5 inches wide x 4 inches high x 11 inches deep (19 x 10.2 x 28 centimeters)
Installation form Workbench (standard) or 19 inch rack mounted chassis (optional)
weight 60.4 pounds (27.4 kilograms), including external pump
Power requirements 100-240 volts AC, 47-63 Hz (automatic detection),<375>375>
~120 watts (analyzer)+150 watts (vacuum pump), during stable operation.