In Picarro's ethylene oxide (EtO) gas concentration analyzer series, the G2920 environmental analyzer uses a platform that supports long-term monitoring of fugitive emissions at fences and EtO concentrations in community environments. In applications that require accurate and real-time quantification of EtO emissions, Picarro outperforms traditional techniques such as Fourier transform infrared spectroscopy (FTIR) or gas chromatography (GC). The quantification of fugitive EtO emissions from industrial facilities has never been so simple.
Best in class sensitivity (ppt level detection limit), specially designed to meet the strictest regulatory requirements
Real time measurement can be used for real-time emission detection (seconds)
Excellent stability and continuous operation can minimize downtime and reduce data loss to the greatest extent possible
Easy to operate, no need to use any consumables, no need for pre enrichment, thus reducing the cost of ownership
Small footprint, can be installed in minutes, and can be deployed in various new application scenarios
High quality stainless steel components, working temperature of 80 ℃, and small volume of key gas channels reduce the possibility of C2H4O molecules adsorbing onto the channel surface, shorten the measurement response time (<10='' seconds), and eliminate measurement deviation. In addition, this analyzer can accurately measure carbon dioxide (CO2), methane (CH4), water vapor (H2O), and other volatile organic compounds (VOCs), ensuring interference free operation of the instrument. The analyzer adopts a portable structure, which is convenient for fixed or mobile deployment (rack can be used), thus achieving on-site activities that have not been feasible so far. The analyzer is equipped with a multi port sampling system, which can characterize air quality from various sources, surpassing the limitations of existing technologies (such as FT-IR) and expanding its service range. With the addition of g2920, picarro now provides a range of easy to integrate solutions for service providers, regulatory agencies, and researchers into the next generation
| G2920 Performance Specifications | mole fraction | Mass Density |
| Detection limit (3)σ, 300 seconds) | 100 ppt | 0.45 μg/m3 ** |
| Zero drift (72 hours)* (Peak to peak, 50 minute average) |
375ppt | 0.68 μg/m3 |
| Accuracy (1)σ, 2 seconds) Accuracy (1 σ, 300 seconds) |
400 ppt+0.1% reading 33 ppt+0.02% of reading |
0.72 μ g/m3+0.1% of reading 0.06 μ g/m3+0.02% of reading |
| Measurement Interval | < 2=''> | < 2=''> |
| response time (Rise time/Fall time 10-90%/90-10%) |
<10>10> | <10>10> |
| Ensure measurement range | 0–2 ppm | 0–3.6E-3 g/m3 |
| Operating measurement range | 0–10 ppm | 0–1.8E-2 g/m3 |
| Compatible with air matrix: • Background • Carbon dioxide • Methane • Water vapor • Ammonia gas |
environment (0–2,000 ppm) (0–10 ppm) (0–30,000 ppm) (0–0.04 ppm) |
environment (0–1.8 g/m3) (0–6.0 E-3 g/m3) (0–22.1 g/m3) (0–2.8 E-5 g/m3) |
*The Picarro analyzer does not require the use of zero point reference gas or zero point gas cylinders to operate or meet specification requirements.
**Convert to μ g/m3 and g/m3 at 1 atmosphere and 25 ° C.
| G2920 System Specifications | ||
| measurement | Cavity ring down spectroscopy (CRDS) technology | |
| Measurement pool temperature and pressure control | ± 0.005 ° C; ± 0.0002 atmospheres | |
| sample temperature | -10 to 80 ° C | |
| Sample flow rate and pressure | 760 pallets is approximately 250 standard milliliters per minute; 300 to 1000 kWh (40 to 133 kPa) | |
| Sample humidity | Relative humidity (RH) less than 99%, no need to dry under non condensing conditions at 40 ° C | |
| Temperature range | 10 to 35 ° C (operating); -10 to 50 ° C (storage) | |
| ambient humidity | Under non condensing conditions, the relative humidity (RH) is less than 85% | |
| Other gases measured (expected performance) | CO2 [Range: 0-2000 ppm; Accuracy (1 σ, 2 seconds): 2 ppm; CH4 [Range: 0-10 ppm; Accuracy (1 σ, 2 seconds): 15 ppb]; H2O [Range: 0-30000 ppm; Accuracy (1 σ, 2 seconds): 100 ppm |
|
| attachment | Accompanying: pump (external), keyboard, mouse Optional: LCD monitor (A0901), 16 channel sampler (A0311, A0311-S), rack mount (A0950) |
|
| Operating system and data output | Windows 10 operating system (RS-232, Ethernet USB、 Data flow; Analog signal (optional) 0-10 volts | |
| Air inlet connector | ¼ inch Swagelok ® SS connector | |
| External dimensions | Analyzer: 17 inches wide x 7 inches high x 17.5 inches long (43.2 x 17.9 x 44.6 centimeters), excluding 0.5 inch feet External pump: 7.5 inches wide x 4 inches high x 11 inches long (19 x 10.2 x 28 centimeters) |
|
| Installation form | Desktop or 19 inch rack mounted chassis | |
| weight | The analyzer weighs 47.0 pounds (21.3 kilograms), and the external pump weighs 14.3 pounds (6.5 kilograms) | |
| Power requirements | 100-240 volts AC; 47-63 Hz (automatic detection); At startup (total) less than 375 watts Steady state operation: 120 watts (analyzer), 150 watts (pump). |
|