title:GC-6890 Chuanhao Gas Chromatography General Improved Equipment
Editor: Chuanhao Instrument Editor 002
Product Features
※ Adopting a large screen LCD Chinese display. Easy to operate and learn
※ It has functions such as self diagnosis, over temperature power-off protection, file storage, calling, and five step program temperature rise, as well as single column automatic compensation function; Can ensure the stability of the baseline during program temperature analysis;
Equipped with six independent temperature control zones and an intelligent rear door opening system, the cooling speed is very fast; Each gasification chamber, detector, and amplifier adopts modular design, making installation and replacement very convenient;
Equipped with a separate and complete capillary analysis system, an independent capillary splitter injector (including diaphragm cleaning, splitting, and tail blowing adjustment). Optional capillary splitter/non splitter injector;
The instrument is equipped with five types of detectors: hydrogen flame detector, thermal conductivity detector, flame photometry detector, electron capture detector, and nitrogen phosphorus detector. Users can choose and select according to their own analysis requirements, or add six way valve injection, conversion furnace device, etc; And it can achieve the series and parallel operation of detectors.
Product Technical Parameters
Temperature control indicators | |
|
Column box: 6 ℃ to 399 ℃ at room temperature Temperature ± 0.1 ℃ Injector and detector: 6 ℃ to 399 ℃ above room temperature Temperature ± 0.1 ℃ |
Program heating stage: Fifth stage Program heating rate: at room temperature6℃~200At ℃0.1℃~40℃/min greater than200At ℃0.1℃~20℃/min |
Detector indicators | |
|
Hydrogen Flame Detector (FID): Sensitivity Mt ≤ 1 × 10-11g/s Noise ≤ 5 × 10-14A linear range ≥ 106 |
Thermal conductivity detector (TCD): Sensitivity S ≥ 5000mv.ml/mg Noise ≤ 20UV linear range ≥104 |
|
Flame photometric detector (FPD): square Formula: S or P filter Sensitivity: 1 × 10-11g (s)/s, 1.4 × 10-12g (p)/s |
Electron Capture Detector (ECD): Sensitivity: Mt ≤ 1 × 10-13g/ml (r-666) Noise ≤ 15UV linear range ≥5×103
|
|
Nitrogen Phosphorus Detector (NPD)): Sensitivity: Nitrogen Mt ≤ 5 × 10-11g/s Phosphorus Mt ≤ 2 × 10-12g/s Noise N ≤ 2 × 10-13A | |
GC-6890 Chuanhao Gas Chromatography General Improved Equipment
Equipment analysis
GC-6890 gas chromatographIt is a cost-effective analytical instrument that is controlled by a microcomputer, operated by a keyboard, and displayed with a Chinese menu on a LCD screen. It has high electronic circuit integration, good reliability, simple operation, memorization of set parameters, no need to reset every time, and is suitable for long-term operation.
The combination of a large column box and a large fan with an automatic rear door cooling system has increased the cooling speed of the column box, truly achieving near room temperature operation. The instrument can flexibly use capillary columns, glass columns, and stainless steel columns. Can perform constant temperature and programmed heating operations.
after-sale service
relevant documents
Auxiliary gas source HF-300 hydrogen generator
★ Main technical indicators
Gas purity:99.999%
Output pressure:0.3Mpa
Traffic:300ml/min
Actual size:240x350x470mm
Power supply voltage: 220V ± 10% 50/60Hz
Power consumption: 120W
Air Generator GA-2009
★ Main technical indicators
Gas purity: oil-free, anhydrous, pure air
Output pressure: 0.4Mpa
Flow rate: 3000ml/min
Actual size: 230x550x360mm
application environment
a) Environmental temperature: 10-40 ℃;
b) Relative humidity: not exceeding 85%;
c) Supply voltage: 220 ± 22V;
d) Power supply frequency: 50 ± 0.5H2
e) Power consumption: 120W;