GC-8801SH helium ionization detector gas chromatograph

NegotiableUpdate on 08/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GC-8801SH helium ionization detector gas chromatograph PDD pulse discharge helium ionization detector system adopts a center cutting and blowback technology with two valves and three columns. The injection, switching, cutting, and blowback processes are automatically controlled by the time program set by the workstation. After being separated by the system, the sample is carried into the detector by a carrier gas. The sample molecules or atoms are ionized by photons emitted by helium gas discharge, generating electrons. The emitted electrons are captured by the collection electrode under the bias electric field, forming a voltage signal. This signal is amplified and processed to form the chromatographic peak of the sample.

Product Details

Instrument configuration:

Our companyGC-8801SHThe helium ionization detector gas chromatograph system is developed in ShimadzuGC-2014COn the basis of gas chromatography, it is modified and equipped with a dedicated chromatography column to analyze impurities in high-purity carbon dioxide or high-purity helium gas. The system includes:

1.ShimazuGC-2014CType gas chromatograph 1 tower

2. VICI PD-D-4-I-SH17-RtypePDDDetector (including purifier)1 cover

3.ShimazuGC-2014 FIDElectrostatic meter1 cover

4.ValcoTen pneumatic valves (with extension rod, protective gas)1 cover

5.ValcoFour way pneumatic valve (with extension rod, protective gas)1 cover

6.Porapak RPolished inner wall filling column3m 1 root

7.Porapak RPolished inner wall filling column4m1 root

8.Molesieve 5APolished inner wall filling column3m 1root

Technical Parameter

GC-8801SHType helium ionization detector gas chromatograph helium ionization detectorIt is a highly sensitive universal detector that has a high response to almost all inorganic and organic compounds, especially suitable for the analysis of high-purity gases,The following isCommon in high-purity gas6Impurity detection limit(ppb):

H2 20ppb

O2 30ppb

N2 30ppb

CH4 20ppb

CO 30ppb

CO2 20ppb