E-mail
bjjkzc01@163.com
-
Phone
15810615463
-
Address
Mapo Xiangyue Sijisan District, Shunyi District, Beijing
Beijing Jingke Zhichuang Technology Development Co., Ltd
bjjkzc01@163.com
15810615463
Mapo Xiangyue Sijisan District, Shunyi District, Beijing
GWJDN-800Type Four Channel High and Low Temperature Dielectric Testing System
Keywords: high temperature dielectric, precision, 800 degrees


Test host four channel high and low temperature probe station
The GWJDN-800 four channel high and low temperature dielectric measurement system is applied to measure and analyze the conductivity and dielectric properties of materials and devices in high-temperature environments. By configuring different testing equipment, different parameters are tested.
1、 Main purpose:
1. Measure the variation of the following parameters with temperature (T), frequency (f), voltage level (V), and bias voltage (Vi):
2. Measure parameters such as capacitance (C), inductance (L), resistance (R), reactance (X), impedance (Z), phase angle (¢), conductance (G), susceptance (B), admittance (Y), loss factor (D), quality factor (Q), etc,
3. Simultaneously calculate the complex dielectric constant (ε) to obtain the conductivity and dielectric properties of the reaction materialr)And the parameter of dielectric loss (D).
4. Can test the dielectric properties of materials and devices in low-temperature environments
2、 Main technical parameters:
1. Temperature range: Room temperature -800 ℃
2. Temperature measurement accuracy 0.1 ℃
3. Heating rate is 1-20. C/min
4. Temperature control mode program control, providing various combination methods such as room temperature, variable temperature, constant temperature, temperature rise, and temperature drop
5. Communication interface RS-485
6. Temperature range 0-800 ℃
7. Test frequencies ranging from 20Hz to 1MHz, 5MHz, and other frequencies are available for selection
8. Electrode Material Platinum Iridium Alloy
9. Measurement accuracy:0.1%;
10. Protect the electrode with a protective electrode to eliminate the influence of parasitic capacitance and boundary capacitance on the test
11. Electrode interference shielding electrode lead with coaxial shielding, sample platform with shielding cover
12. Software function: Automatically analyze data, classify and save, combine samples and measurement plans to generate experimental plans required by the system, and output TXT, XLS, BMP and other format files
13. The measurement scheme provides flexible and rich testing settings, including frequency spectrum, impedance spectrum, dielectric spectrum, and their combinations
14. Interface methods: including various LCR interfaces such as Keysight, Wayne, Kerr, Tonghui, etc,
15. Dimensions L360mm * W370mm * H510mm
16. Net weight 22KG