Welcome Customer !

Membership

Help

Beijing Lijia United Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Beijing Lijia United Technology Co., Ltd

  • E-mail

  • Phone

    13910499766

  • Address

    Building 5, Guanghua Entrepreneurship Park, No. 18 Anningzhuang East Road, Haidian District, Beijing

Contact Now

GasScouterTM G4301 mobile gas concentration analyzer measures CO2, CH4, and H2O

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Specially designed for mobile science research trends.
Product Details

Picarro GasScouter ™ G4301 is a new generation of lightweight and convenient battery powered gas concentration analyzer designed specifically for mobile scientific research trends. This analyzer is a perfect mobile solution for achieving high-precision greenhouse gas measurements in the world's most challenging remote environments.

High precision (ppb) measurement of CO2 and CH4 concentrations

Convenient, lightweight (25 pounds), low-power (25 W) backpack

Built in rechargeable lithium-ion battery, capable of running continuously for up to 8 hours

Built in WiFi, allowing for mobile operations at remote locations using a tablet or smartphone

Integrated vacuum pump, suitable for various on-site applications

GasScouterTM G4301 移动式气体浓度分析仪 测量 CO2、CH4 和 H2O

GasScouter can synchronously and continuously measure the concentrations of CO2, CH4, and H2O over a wide dynamic range, thereby achieving effective background and emission measurements. Especially in remote areas, this feature makes the GasScouter analyzer an ideal choice for effectively and accurately identifying and quantifying greenhouse gases from biological and anthropogenic sources. GasScouter is also an excellent soil flux measurement instrument. The sampling system is equipped with an integrated pump. This analyzer can be used for continuous on-site mapping or closed-loop configuration for soil chamber research, making it a universal analyzer for field applications.

Picarro G4301 GasScouter Performance Specifications
Performance specifications CO2 CH4 H2O
Initial accuracy (5 seconds) 0.4 ppm+0.1% reading
Typical value=0.15 ppm*
3 ppb+0.1% reading
Typical value=0.8 ppb*
100 ppm+5% reading
Accuracy (300 seconds, 1 σ) 0.04 ppm+0.02% reading
Typical value=0.025 ppm*
0.3 ppb+0.02% reading
Typical value=0.1 ppb*
10 ppm+5% reading
Detection limit (300 seconds, 3 σ) 0.12 ppm
Typical value=0.075 ppm*
0.9 ppb
Typical value=0.3 ppb*
Drift (the difference between the maximum values of the 24-hour and 50 minute averages) 0.5 ppm
Typical value=0.18 ppm*
1 ppb
Typical value=0.56 ppb**
measuring range 0–3% 0–800 ppm 0-3% (under non condensing conditions)
Measurement Interval 3 seconds
Response time (0-20 ppb)
(Rise time/Fall time 10-90%/90-10%)
5 seconds
*The typical performance is defined as the median test results of 29 G4301 analyzers produced sequentially, measured at ambient concentration levels
Picarro G4301 GasScouter System Specifications
operation temperature 10–45 ℃
ambient humidity <>
External dimensions 14 inches wide x 6.95 inches thick x 18.2 inches high (35.6 x 17.7 x 46.4 centimeters)
Sample flow rate Built in vacuum pump, approximately 1 standard liter (slm) per minute at atmospheric pressure
Vacuum pump exhaust (circulating in a 1-liter chamber) < 0.1='' ppb=''>
< 1='' ppb=''>
weight 23 pounds (10.4 kilograms)
power consumption 25 watts
battery Built in lithium battery, 223 watt hours. Input/output voltage is 12-19 volts, and it takes 5-8 hours to fully charge.
Sample inlet/outlet connection Colder valve free quick connect port
data output USB (x2), Wi Fi network
operating system Windows 10 Professional Edition
Picarro G4301 GasScouter Accessories
GPS device (A0946) GPS antenna and module (connected via USB). Including software upgrade for Picarro to report GPS parameters in raw data, data files can be exported in KML format.
Mobile Environmental Soil Flux System (A0947) Gas flux chamber (stainless steel, with components that can quickly disconnect inlet and outlet connections) and flux calculation software.