Test function
|
measurement parameters
|
time-consuming
|
Remarks
|
|
Steady state testing
|
Voltage (U: V), current (I: A), active power (P: W), power factor (P: F), apparent power (S: VA), reactive power (Q: Var), active energy (Ep: W · h), reactive energy (Ep: Var · h)
|
1 second/time
|
|
|
waveform
|
All waveforms, voltage waveform, current waveform, phase separated waveform, waveform data: voltage modulation rate, voltage peak value Upk, voltage peak coefficient Ucf, voltage distortion rate, current peak value Ipk, current peak coefficient Icf
|
||
|
harmonic
|
Voltage total harmonic (waveform distortion rate), current total harmonic; Harmonic bar chart, voltage deviation system, voltage and current harmonics (frequency 1-59, intermediate frequency 1-29); Telephone harmonic factor (power frequency)
|
||
|
Setting test
|
Voltage setting rise range, relative voltage setting rise range;
Voltage setting drop range, relative voltage setting drop range;
Frequency setting rise range, relative frequency setting rise range;
Frequency setting decrease range, relative frequency setting decrease range;
|
100 seconds
|
Simultaneously conduct three-phase and average value tests
|
|
Wave testing
|
Maximum and minimum fluctuation voltage, steady-state voltage deviation;
Maximum and minimum fluctuation frequencies, steady-state frequency band cold and hot voltage change rates
|
60 seconds
|
|
|
Sudden testing (loading)
|
The minimum instantaneous voltage that decreases during loading, transient voltage deviation, and voltage recovery time after increasing the load; (Implemented by system buttons)
The lowest instantaneous frequency that decreases during loading, the transient frequency deviation, and the frequency recovery time after increasing the load;
|
12 seconds (power frequency) 6 seconds (intermediate frequency)
|
|
|
Sudden unloading test (load reduction)
|
The highest instantaneous voltage that rises during unloading, transient voltage deviation, and voltage recovery time after load reduction; (Implemented by system buttons)
The highest instantaneous frequency that rises during unloading, transient frequency deviation, and frequency recovery time after load reduction;
|
||
|
waveform recording
|
Three phase voltage waveform; Four recording modes: Umod (peak value, 256 points), 2000 points/second, 4000 points/second, Har (harmonic mode, power frequency 128 points/cycle, intermediate frequency 64 points/cycle)
|
Record 28160 points per phase
|
Three phase simultaneous waveform recording
|