Glossiness and Image Clarity (DOI) Meter

NegotiableUpdate on 04/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The ISO 408 Gloss and Image Clarity (DOI) Meter provides glossiness measurement technology that enables accurate analysis of glossiness, haze, and image clarity (DOI) for a single reading. Accurate, fast, and simultaneous measurement of glossiness, haze, image clarity (DOI), Z-high reflectivity (RsPEC), reflective image quality (RIQ), and angular photometric curves. Each instrument can provide calibration certificates that comply with ISO 17025, UKAS, and BAM

Product Details

ISO 408 Glossiness and Image Clarity (DOI) Meter

The glossiness measurement technology provided by the Engel 408 enables precise analysis of glossiness, haze, and image clarity (DOI) for a single reading.

accuracy

  • Quickly and simultaneously measure glossiness, haze, image clarity (DOI), maximum reflectance (RsPEC), reflectance image quality (RIQ), and angular photometry curve
  • Each instrument can provide calibration certificates that comply with ISO 17025, UKAS, and BAM

simple

  • LCD display screen, clear and easy to read, displaying glossiness values, statistical parameters, and charts
  • Users can define the display of measurement values
  • Each set of readings is stamped with time and date stamps

flexible

  • Three (20/60/85 °) angle versions with the highest precision and resolution, suitable for all glossiness applications
  • Through Bluetooth®Download via Bluetooth or USB to ElcoMaster®In data management software, used for real-time analysis

durable

  • The sturdy aluminum alloy structure ensures optical stability
  • Continuous operation for more than 17 hours, or obtaining more than 20000 readings
  • Compact and portable instrument with integrated calibration plate holder

Efficient

  • Simple menu style multilingual user interface
  • Clear and bright display screen, backlit to show up to five screen display parameters
  • Ability to perform built-in trend analysis on glossiness and image quality (IQ) values

Powerful functionality

  • Built in memory, capable of storing 999 comprehensive readings of angle measurement and photometry
  • The built-in battery can be fully charged within 2.5 hours

Definition of Glossiness and Image Clarity (DOI) Meter

gloss 2

Glossiness (GU)

A simple unit of measurement that is directly proportional to the amount of light reflected from a surface, reflecting the glossiness of the surface.

The surface texture will reduce the appearance quality, but it will not affect the glossiness. Use a standard glossiness meter to measure two types of test panels, and the readings are the same.

haze combined

Fog Shadow (HU) and Fog Shadow Value (HU Log)

High quality glossy surface appearance is transparent, deep, and bright. Fog shadows can cause a decrease in reflection contrast and the appearance of halos around light sources, all of which greatly reduce visual effects.

In addition to measuring glossiness and image clarity (DOI) like traditional gloss meters, the Jig 408 can also measure haze units according to the ASTM D4039 standard.

rspec

Zui High Reflectivity (RsPEC)

Measuring from a very narrow angle in the mirror direction can yield the highest reflectivity, which is highly sensitive to any surface texture, ripple, or undulation. When the maximum reflectivity equals glossiness, the surface is smooth. As the surface texture increases, the maximum reflectivity decreases.

doi

Image clarity (DOI)

Image clarity is used to measure the clarity of the reflected image on the coating surface. Similar coatings may have the same glossiness value, but the visual effect may be significantly different. Coatings with poor visual effects may have many undulating patterns, commonly known as "orange peel". Observing the reflective object from the coating, the image becomes blurry and distorted.

The reading for the undistorted value of the surface image is 100. When the value decreases, the image becomes more distorted.

riq

Reflective Image Quality (RIQ)

When evaluating the mirror/scattering factors of high reflectivity coatings and low gloss materials, RIQ is very sensitive.
If the surface image is not distorted, the value will be restored to 100. As the value decreases, surface patterns increase and image clarity decreases.

gonio

Angular photometric curve

The glossiness, haze, image clarity (DOI), and maximum reflectance (RsPEC) values detected by the Jig 408 can be used to evaluate the visual effects of any surface. To gain a detailed understanding of specular reflectance, you can download all angular photometric curves to your computer. It is also possible to quantify the appearance of orange peel or non-standard coatings (low image clarity) using the Jig 408.

Elcometer 408

Elcometer 408

enclosure

Product Features

The menu structure is convenient and easy to understand

English, Spanish, French, Italian, German, and Chinese

Bright color screen; Continuous backlight

Adjustable brightness, with a touch sensitive interface with 6 buttons

User defined measurement display

Scratch resistant and solvent resistant display screen

Power supply or USB power supply

Calibration certificate: traceable to ISO, UKAS, and BAM

data output

USB connection to computer

Bluetooth®*(Bluetooth): Connect to a computer or Android ™ Mobile devices

Screen data statistics

x. σ, maximum and minimum values

ElcoMaster®Software&USB cable

Date and timestamp

Instrument memory; Number of memorable readings

Up to 999 readings and curves

Repeated measurement mode

User defined: 2, 5, or 10 seconds

Delete the last reading after Zui

Standard and fixed batch sizes

Change trend, glossiness, and image map

Measurement mode

Glossiness (GU): 20 °, 60 °, 85 ° *; Fog Shadow (HU) and Fog Shadow Value (HU Log); Image clarity (DOI); Zui high reflectivity (RsPEC); Reflection Image Quality (RIQ) and Angular Intensity Curve

technical specifications

certificate

Part number

Product Description

J408--26

Dual angle (20 and 60 degrees)

J408--268

Dimensionality (20, 60, and 85 degrees)

Battery type

Rechargeable lithium-ion batteries have a battery life of up to 17 hours and can perform 20000 readings

Charging time

USB -4.5 hours, power charger -2.5 hours

gloss

Fog Shadow

Image clarity (DOI)

Reflective Image Quality (RIQ)

Angular photometry

measuring range

20°: 0-2,000GU;
60°: 0-1,000GU;
85°: 0-150GU

0-2,000GU

0-100 DOI

0-100 RIQ

-

resolving power

0.1GU

0.1HU

0.1

0.1GU

Repeatability

0.2GU

0.2HU

0.2

0.2GU

Reproducibility

0.5GU

0.5HU

0.5

0.5GU

The highest specular reflectance at 20 ° C

± 0.09375°

Dimensions (H x W x D)

65 x 140 x 50mm (2.5 x 5.5 x 1.9”)

weight

790g (1lb 12oz)

Packaging List

Elcometer 408、 ISO 17025 high gloss calibration plate with calibration certificate, gloss plate cleaning cloth, power charger (UK, EU, and US), shipping packaging box, USB cable ElcoMaster®Software and operation manual.

Standard:
AS/NZS 1580.602.2, ASTM C 584, ASTM D 1455, ASTM D 2457, ASTM D 4039, ASTM D 523, ASTM D 5767, DIN 67530, ECCA T2,
EN 12373-11, EN 13523-2, ISO 2813, ISO 7668, JIS K 5600-4-7, JIS Z 8741, TAPPI T 653

The standard configuration includes a calibration certificate
# Only real-time data available

* Bluetooth®Currently not available in Japan

Elcometer 408

technical specifications

T40823532

ISO 17025 high gloss calibration plate with calibration certificate

T40823533

Mirror glossiness calibration board with calibration certificate

T99923535

Gloss board cleaning cloth

T99921325

USB line