One Product Description: This instrument is a differential pressure air leakage tester used to check the airtightness of various products. By using the standard error correction function and temperature compensation function, high-precision and short-term testing that has been difficult to achieve in harsh environments for a long time has been solved. And it has strengthened the quality management function, channel function, and communication function. At the same time, it improves the differential pressure resolution and operational convenience, enabling automated testing of all test samples under different conditions. II Main features: Chinese display, parameter setting, and simultaneous display of test pressure, pressure difference, leakage rate, and monitoring of the entire leakage process; Four different testing channels and multiple independent detection parameters for different workpieces under the same pressure can be set simultaneously; The leak detection data acquisition function adopts digital transmission, high fidelity, high reliability, and high precision, with stable resolutions of up to 0.1Pa and 1Pa. The RS-232C interface output facilitates the storage, processing, and analysis of test data; The intelligent automatic leakage meter can automatically measure the equivalent content volume K (Ve) value (option), and store this value for actual inspection, converting the measured differential pressure into a leakage flow rate value (ml/min), making precise leakage measurement possible (manually input volume); The high brightness alarm function test has been completed, and the high brightness light prompt of the tester can clearly view the test results without causing visual errors. III Specification: Test pressure: 0-50KPa, 50-200KPa, 100-3000KPa, -100KPa, -0.1Pa, resolution: 0.1Pa/1Pa; Display unit: M

Product Details

One Product Description:
This instrument is a differential pressure air leakage tester used to check the airtightness of various products. By using the standard error correction function and temperature compensation function, high-precision and short-term testing that has been difficult to achieve in harsh environments for a long time has been solved. And it has strengthened the quality management function, channel function, and communication function. At the same time, it improves the differential pressure resolution and operational convenience, enabling automated testing of all test samples under different conditions.

II Main features:

  1. Chinese display, parameter setting, and simultaneous display of test pressure, pressure difference, leakage rate, and monitoring of the entire leakage process;
  2. Four different testing channels and multiple independent detection parameters for different workpieces under the same pressure can be set simultaneously;
  3. The leak detection data acquisition function adopts digital transmission, high fidelity, high reliability, and high precision, with stable resolutions of up to 0.1Pa and 1Pa;
  4. The RS-232C interface output facilitates the storage, processing, and analysis of test data;
  5. The intelligent automatic leakage meter can automatically measure the equivalent content volume K (Ve) value (option), and store this value for actual inspection, converting the measured differential pressure into a leakage flow rate value (ml/min), making precise leakage measurement possible (manually input volume);
  6. The high brightness alarm function test has been completed, and the high brightness light prompt of the tester can clearly view the test results without causing visual errors.

III Specifications:

  1. Test pressure: 0-50KPa, 50-200KPa, 100-3000KPa, -100KPa, -0.1Pa, resolution: 0.1Pa/1Pa;
  2. Display unit: Mpa kpa ml/min pa;
  3. Accuracy: 0.075%;
  4. Inflation time/holding time/testing time: 0.1-999.9S;
  5. Temperature range: -10 ℃ to 40 ℃ (please specify when used under high temperature conditions) Humidity range: below 80% RH but without condensation;
  6. External port: RS-232 serial communication port;
  7. Purified compressed air pressure: 0.45-0.8Mpa;
  8. Power supply voltage: AC220V ± 10% 50/60Hz.

4 The usual work process is divided into the following four steps:

  1. Simultaneously fill the test sample and standard sample with compressed gas at a predetermined pressure;
  2. Cut off the connection between the test sample, standard sample, and inflation gas source, while forming a closed chamber for each of the test sample and standard sample. Use a differential pressure sensor to sense the pressure difference between the test sample and standard sample;
  3. After a period of time, the differential pressure sensor (DPS) detects the internal pressure difference caused by leakage, thereby detecting the amount of workpiece leakage;
  4. Discharge the gases from the test samples, standard samples, and system pipelines into the atmosphere to complete a testing cycle.