HYCT series residual current transformer

NegotiableUpdate on 05/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HYCT series residual current transformer is the terminal acquisition module of electrical fire detectors, which works together with electrical fire detectors to achieve signal acquisition, processing, and uploading.

Product Details


FUNCTIONAL OVERVIEW

The HYCT series residual current transformer is the terminal acquisition module of electrical fire detectors, which works together with electrical fire detectors to achieve signal acquisition, processing, and uploading. The HYCT series residual current transformer is designed for high-precision residual current acquisition, with good linearity and high sensitivity. The product is suitable for distribution circuits with different rated currents, and can be selected in two specifications: cables and copper bars.

Scope of application: Suitable for leakage current detection of power lines in various factories, warehouses, offices, commercial buildings, hotels, residential and entertainment venues, etc. Used in conjunction with monitoring equipment to achieve monitoring and alarm, effectively ensuring safe use of electricity and preventing electrical fires.

Execution standard: The design, manufacturing, and inspection of HYCT series residual current transformers comply with the national standard GB14287.2-2014 "Electrical Fire Monitoring System Part 2: Residual Current Electrical Fire Monitoring Detector".

Technical Parameter

model

Main circuit

reference current

Alarm Range

accuracy class

General parameters

HYCTY-045

0~100A

300mA-1000mA continuously adjustable

Level 0.5

Rated primary current: 1000mA

Rated secondary current: 0.5mA

Rated continuous thermal current: 2A

Lower limit temperature: -20 ℃

Upper limit temperature: 70 ℃

Secondary load: 90 Ω

HYCTY-065

100~250A

HYCTY-080

250~400A

HYCTY-105

400~630A

HYCTF-2550

400~630A

HYCTF-3260

630~1250A


Model Selection Table

Transformer model

Main circuit

reference current

Dimensions L * W * H (mm)

Inner diameter dimension D (a * b) (mm)

Thread type

HYCTY-045

160A

88*93*45

Ø49

cable

HYCTY-065

250A

110*119*45

Ø65

HYCTY-080

400A

133*143*45

Ø80

HYCTY-105

630A

159*168*45

Ø105

HYCTF-2550

630A

316*133*45

250*50

Copper Bar

HYCTF-3260

1600A

423*176*60

325*62

Instructions for threading method

Three phase distribution system: A, B, C, N pass through transformers simultaneously;


Single phase distribution system: L and N pass through transformers simultaneously;