【Handheld online conductivity detectorFunction Overview:
Industrial pH transmitter is a device for measuring the pH value (hydrogen ion concentration index, acidity and alkalinity) of a solution, with automatic temperature compensation function, and can switch between automatic and manual temperature compensation at will.
The optical detection method of the dissolved oxygen measurement probe for water quality can effectively measure the molecular oxygen dissolved in water and eliminate the interference of pH fluctuations, ammonia nitrogen and other chemicals or heavy metals in the water, thereby providing more stable and accurate measurement results over a longer period of time.
The water quality conductivity is a device used to measure the conductivity value of a solution, which has an automatic temperature compensation function and can compensate the current temperature conductivity to a specified temperature.
Basic conventional water quality monitoring digital turbidity transmitter with built-in temperature transmitter, capable of automatic temperature compensation, suitable for long-term online monitoring environments.
This product is suitable for continuous monitoring of cross-sectional water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food and tap water solutions, industrial wastewater, domestic wastewater, agriculture, aquaculture industries, and other scenarios.
【Handheld online conductivity detectorDetection principle: The reference solution inside the electrode glass bubble is affected by the pH of the measured solution, causing the electrode to generate an electromotive force (voltage), and the magnitude of the electromotive force reflects the pH of the measured solution. Dissolved oxygen is measured using fluorescence method, which does not consume oxygen and does not require electrolyte. The measured value of solution conductivity is calculated based on the resistance presented by the electrode and the constant K of the electrode itself, and obtained through temperature compensation. Adopting the mature 90 ° scattered light principle from abroad, using the design method of infrared LED light source and fiber optic transmission optical path; At the same time, an internal filtering algorithm is added, which has strong resistance to external light interference.
: RS485
[Power supply mode]: 7-30VDC.
[Average power consumption]: PH0.3W.
Core component temperature resistance: 0~+80 ℃
Waterproof rating: IP68
Equipment pressure resistance: 0.6MPa
【 Equipment size 】: Length 266mm, outer diameter 30mm.
: Both the upper and lower threads are NPT3/4 threads, making it convenient for pipeline installation and submerged installation.
: The electrode has a service life of about one year, and should be replaced with a new electrode in a timely manner after aging.
【 Measurement elements 】: PH, water temperature.
[PH parameter description]:
Measurement range: 0~14.00PH.
Typical accuracy: ± 0.15PH.
Repetitive error: ± 0.02PH.
Resolution: 0.01PH.
[Temperature parameter description]:
The composite electrode is equipped with a temperature sensor and comes with a temperature compensation function in the program. Manual compensation and automatic compensation can be switched freely.
In manual compensation mode, the default compensation temperature is 25 ℃, and the compensation temperature can be set by oneself.
Measurement range: 0~60 ℃.
Typical accuracy: ± 0.5 ℃.
Resolution: 0.1 ℃.
: 0~40 ℃
:
● Regular type: 170mm in length and 30mm in outer diameter. (Standard regular type)
Economic type: 170mm in length and 30mm in outer diameter.
● Flow type: Length 205mm, outer diameter 30mm.
:
● Conventional type: Top NPT3/4 thread.
Economy type: Top NPT3/4 thread.
● Flow type: Both upper and lower threads are NPT3/4 threads, making it convenient for pipeline installation and submerged installation.
: The usage cycle is about one year, and the fluorescent film should be replaced with a new one in a timely manner after aging.
Response time: ≤ 60s
【 Shell Material 】:
● Conventional type: corrosion-resistant plastic shell, stainless steel fluorescent film head.
Economic type: corrosion-resistant plastic shell, plastic shell material film head.
● Circulation type: corrosion-resistant plastic shell, plastic shell material film head.
【 Measurement elements 】: dissolved oxygen saturation, dissolved oxygen concentration, water temperature.
Explanation of dissolved oxygen parameters:
Measurement range: 0-20mg/L (0-200% saturation).
Typical error: ± 3% FS.
Resolution: 0.01mg/L, 0.1%.
[Temperature parameter description]:
Measurement range: 0~40 ℃
Typical accuracy: ± 0.5 ℃
Resolution: 0.1 ℃
Core component temperature resistance: -20~+80 ℃
【 Equipment size 】: Length 266mm, outer diameter 30mm.
: Both the upper and lower threads are NPT3/4 threads, making it convenient for pipeline installation and submerged installation.
: The electrode has a service life of about one year, and should be replaced with a new electrode in a timely manner after aging.
【 Measurement elements 】: Water quality EC, water temperature, salinity TDS
[EC Parameter Description]:
When the electrode constant K=1, the measurement range is 1~2000 μ s/cm;
When the electrode constant K=10, the measurement range is 10-20000 μ s/cm;
Typical accuracy: ± 1% FS.
When the electrode constant K=1, the resolution is 0.1 μ s/cm;
When the electrode constant K is 10, the resolution is 1 μ s/cm;
[Temperature parameter description]:
Measurement range: -5~+80 ℃
Typical accuracy: ± 0.5 ℃
Resolution: 0.1 ℃
Temperature compensation range: -5~+80 ℃ (default compensation temperature 25 ℃)
● Temperature compensation coefficient: default 0.02
Salinity parameter description:
When the electrode constant K=1, the measurement range is 0~1000ppm;
When the electrode constant K=10, the measurement range is 0~11476ppm.
TDS parameter description:
When the electrode constant K=1, the measurement range is 0-1100ppm;
When the electrode constant K=10, the measurement range is 0~13400ppm.
: 0~40 ℃
: length 134mm, outer diameter 30mm.
: The thread is 3/4 thread, which is convenient for installation.
: Approximately 2 years of normal use.
Response time: ≤ 30s
【 Shell Material 】: Corrosion resistant plastic shell or stainless steel shell is optional.
【 Measurement elements 】: turbidity, water temperature
Turbidity parameter description:
Measurement Range: Four optional ranges: 0~50NTU, 0~200NTU, 0~1000NTU, and 0~4000NTU
Typical accuracy: ± 5% FS (25 ℃).
0-50NTU range resolution: 0.01NTU;
Range resolution of 0~200NTU and 0~1000NTU: 0.1NTU;
● 0-4000NTU range resolution: 1NTU
[Temperature parameter description]:
Measurement range: 0~40 ℃
Typical accuracy: ± 0.5 ℃
Resolution: 0.1 ℃
Waterproof rating: IP68
Equipment pressure resistance: 0.6MPa
Product Features:
ARM Cortex-M3 architecture processor, Android system.
Standard Type-C charging allows for direct use of a mobile phone charger to charge the device.
Continuous detection, data collection time can be set in minutes.
● Support calibration
● Equipped with automatic temperature compensation function, supporting manual temperature compensation
● Supporting dedicated PH transmitter
● It has a reading lock function (automatic reading), and the measurement result is the final result without conversion or calculation
The test results can be uploaded.
The test results can be exported to an Excel spreadsheet and viewed by connecting to a computer.
The storage capacity for test results is 5 million, supporting data storage and retrieval.
● Supports Wi Fi, and the detection results are directly transmitted to the regulatory platform
A 3.5-inch color touch screen provides a better user experience.
● Equipped with automatic backlight and automatic shutdown functions;;
P68 protection level.