-
Phone
15021595718,15121127657
-
Address
Jiading Industrial Park, Shanghai
Shanghai Xuansheng Scientific Instrument Co., Ltd
15021595718,15121127657
Jiading Industrial Park, Shanghai
Hebei Pipeline Natural Gas Online Detection System Device Chromatography
Advantages of online natural gas detection equipment:
1. The instrument has good stability and durability, and can work 24 hours a day without stopping, meeting the requirements of high-intensity online detection.
2. By adopting IoT technology, it can be installed in multiple locations within the detection area, achieving regional networking, multi-point monitoring, and key monitoring.
3. Adopting modular design, functions can be customized according to user requirements and on-site environment to meet customer needs.
4. Stable and secure operation, unmanned operation, and low maintenance costs.
5. Real time temperature and pressure compensation, suitable for various environmental conditions.
6. High stability temperature control system, with a temperature control accuracy of 0.01 ℃.
7. Self protection function; When the gas supply is insufficient, the bridge flow will be automatically disconnected. Protect the TCD tungsten wire of the instrument from damage.
8. Automatic resumption of operation: After power on, gas supply restoration, or unexpected power outage restoration, the method of automatic ignition and operation.
9. Support remote alarm and remote diagnosis functions.
Hebei Pipeline Natural Gas Online Detection System Device Chromatography
Gas detection parameters:
1. Carrier gas: high-purity hydrogen (purity ≥ 99.995%) Hydrogen pressure: 0-0.4Mpa Hydrogen flow rate: 0-300ml/min
2. The built-in calorific value software automatically calculates the component content, high calorific value, low calorific value, density, relative density, Hua Bai number, and combustion potential, Dual channel simultaneous operation
3. TCD sensitivity S ≥ 3500mv. ml/mg (benzene) noise ≤ 0.02mv
Sensitivity: S ≥ 3500mv.ml/mg
噪 音: N≤0.01mv
Drift: L ≤ 0.02mv/H
Integral sensitivity: 0.05uV.S
4Built in injection valve: automatic injection, automatic reset (module control)
5.Temperature control accuracy: better than ± 0.1 ℃
6.Temperature gradient: ≤ 1%
7.Heating rate: 0-40 ℃/min
8. Qualitative time error: ≤ 0.02min
9. Detection error:0.1%
10.Voltage range: -1.3V-1.3V
11.Integral sensitivity: 0.05uV.S
12.Small resolution: 1mV
13.Dynamic range: 10-7
14.Linearity: ± 0.005%
15.Analysis time: within 15 minutes
16.High power: 500W
17Working environment: -10 ℃ -60 ℃; humidity: 10% -85%
18Input power supply: AC220V