Hydrogen chloride/fluoride analyzer (HCl, HF, H2O)

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Simultaneously measure the concentrations of HCl, HF, and water vapor in the atmospheric environment or industrial processes.
Product Details

氯化氢/氟化氢分析仪(HCl,HF,H2O)

LGR (currently under ABB Canada)Newly launched hydrogen chloride/Hydrogen fluoride analyzerCan simultaneously measure atmospheric environment or industrial processesHClHFHigh precision and sensitivity in relation to water vapor concentration. The analyzer can provide measurement speed in seconds, while achieving accuracy ofppbGrade. The test results indicate that the analyzer is not affected by other gas types and pressures.
The analyzer adoptsLGROutput spectrum of off-axis integrating cavity with patented design(OA-ICOS)Technology (patent number: 6795190), which eliminatesCRDSDuring the measurement process, technology requires continuous matching of the optical cavity and laser wavelength to improve the weak signal intensity, eliminating the need for complex laser alignment adjustment, temperature control, and wavelength monitoring in the analyzer. Real time display of high-resolution laser absorption spectra. Using a built-in computer(Linux OS)To provide continuous storage and measurement of data. With remote control function, users can operate the analyzer from any location through the network, and can also share real-time data and perform instrument diagnosis through remote login.
characteristic:
1.moreFast measurement response
2. The concentration measurement range is wider
3. Low energy consumption, more suitable for field applications
4. useLGRTemperature control technology achieves smaller drift and higher stability
5. HClWithHFSimultaneous measurement
Performance indicators:
Repeatability/Accuracy(5second/ 100Seconds)
HClHF2 ppb / 0.2 ppb
Drift(EPType,15Minute average, standard temperature and pressure,24Hour)
HClHF1ppb
Measurement range (under all technical specifications):
HClHF0.2~2000 ppb
Optional range
HClHF0~10 ppm
Measurement speed:
0.01~1 Hz(Flow rate response <6Second, optional external pump needs to be configured)
Environmental conditions:
Sample temperature:-10~80
Operating temperature:0~45
ambient humidity:0~100% RH, without condensation
Output:
Number(RS 232)Simulation, EthernetUSB
Electricity demand:
115/230 VAC50/60 Hzperhaps12 VDC
Power:100 W(Standard type)/ 150 WEPType)
Size and weight
Standard type22.2 cmHx 48.3 cmWx 61 cmD),29.5 kg
EPtype35.6 cmHx 48.3 cmWx 61 cmD40.8 kg
Ordering information:
Model number(Model):
907-0038(Standard type, rack mounted)
911-0038EPtype, rack mounted)
Optional items:
1. 908-0003-9001orMIU-377-1616Road multiplexer
2. 908-0003-9002orMIU-374-88Road multiplexer
3. 908-0008-9009N920Vacuum pump (gas update time)1.2 Seconds)
4. 904-0002Data collection software (includingUSB/RS 232Cable), capable of recording and synchronizing multiple devicesLGRAnalyzer or other equipment (such asGPSData output from anemometers, etc
manufacturer:
ABB Canada