- Phone
-
Address
Room 1705, Tianhe Commercial Building, No. 8 Zhongshan Avenue, Guangzhou
Guangzhou Yitong Instrument Equipment Co., Ltd
Room 1705, Tianhe Commercial Building, No. 8 Zhongshan Avenue, Guangzhou
Hydrolab multi parameter water quality analyzer is a new type of multi parameter, wide range water quality analyzer that can be used for online and portable monitoring of water quality in different water bodies such as surface water, groundwater, source water, drinking water, sewage discharge outlets, and marine water. Compared to conventional five parameter analyzers, the Hydrolab multi parameter water quality analyzer can monitor more parameters: dissolved oxygen, pH, ORP (oxidation-reduction potential), conductivity (salinity, total dissolved solids, resistance), temperature, depth, turbidity, chlorophyll-a, blue-green algae, rhodamine WT, ammonium/ammonia ions, nitrate ions, chloride ions, ambient light, and total dissolved solids, totaling 15 parameters.
Product Features:
Multi parameter integrated measurement, widely applicable
Online and portable without any compromise
Easy and convenient operation
Comes with built-in memory, can independently form a field observation station
L has automatic cleaning function and requires minimal maintenance
Good waterproof performance, with a maximum depth of 225 meters underwater
Dedicated handheld terminal for on-site reading of real-time data
Hydrolab Multi Parameter Water Quality Analyzer (Conventional Five Parameter Analyzer) Host Size:
DS5/DS5X: Outer diameter: 8.9 cm; Length: 58.4 cm
MS5: Outer diameter: 4.4 cm; Length: 74.9 cm (with battery compartment)
Product advantages:
The Hydrolab multi parameter water quality analyzer has advantages such as small size, in-situ monitoring, lightweight and portable use, low power consumption, and can be powered by solar energy.
Application industry:
Hydrolab multi parameter water quality analyzer is widely used in surface water, groundwater, source water, drinking water, sewage discharge outlets, oceans and other fields.
| Multi parameter analyzer (Hydrolab 5 series) | |
|---|---|
| Technical Specifications | |
| (1) DS5/5X host | |
| 1) Outer diameter | 8.9cm(DS5、DS5X),4.4cm(MS5) |
| 2) Length | 58.4cm(DS5、DS5X),76.9cm(MS5) |
| 3) Weight (typical configuration) | 3.35 kg (DS5, DS5X), 1.3 kg (MS5) |
| 4) Maximum depth | 225m |
| 5) Operating temperature | -5 to 50 ℃ |
| 6) Battery supply (optional) | 8 dry batteries |
| 7) Computer interface | RS232、SDI-12、RS485 |
| 8) Memory (optional) | 120000 measurement values |
| (2) Temperature sensor | |
| 1) Scope | -5 to 50 ℃ |
| 2) Accuracy | ± 0.10℃ |
| 3) Resolution | 0.01℃ |
| 4) Method | Thermistor method |
| (3) Conductivity sensor | |
| 1) Scope | 0~100mS/cm |
| 2) Accuracy | ± 1% of the reading; ±0.001mS/cm; |
| 3) Resolution | 0.0001 units |
| 4) Method | Four graphite electrode method |
| (4) PH sensor | |
| 1) Scope | 0-14 units |
| 2) Accuracy | ± 0.2 units |
| 3) Resolution | 0.01 units |
| 4) Method | Glass electrode method |
| (5) Fluorescence based dissolved oxygen sensor | |
| 1) Scope | 0~60mg/L |
| 2) Accuracy | ± 0.1 mg/L for ≤ 8 mg/L, ± 0.2 mg/L for>8 mg/L, and ± 10% of the reading for>20 mg/L |
| 3) Resolution | 0.01mg/L |
| 4) Method | fluorescence method |
| (6) Self cleaning turbidity | |
| 1) Scope | 0~3000NTU |
| 2) Accuracy | Within 100NTU is ± 1%, 100-400NTU is ± 3%, and 400-3000NTU is ± 5%; |
| 3) Resolution | Within 400NTU is 0.1400~3000NTU is 1.0; |
| 4) Method | Infrared dual beam optical method |
| (7) Chlorophyll a | |
| 1) Scope | Low sensitivity: 0.03~500 μ g/L; Medium sensitivity: 0.03~50 μ g/L; High sensitivity: 0.03~5 μ g/L; |
| 2) Accuracy | ±3% |
| 3) Resolution | 0.01μg/L |
| 4) Method | In vivo fluorescence method |
| (8) Blue-green algae | |
| 1) Scope | Low sensitivity: 100-2000000 cells/mL; Medium sensitivity: 100-200000 cells/mL; High sensitivity: 100-20000 cells/mL; |
| 2) Accuracy | ±3% |
| 3) Resolution | 0.01cells/mL |
| 4) Method | fluorescence method |