Phone
18752030246
-
Address
Room 201, Building 8, 777 Longwu Road, Xuhui District, Shanghai
Shanghai Shujun Instrument Equipment Co., Ltd
18752030246
Room 201, Building 8, 777 Longwu Road, Xuhui District, Shanghai
Application of analysis function:
◆ 1D electrophoresis gel analysis
Dot blot analysis
Analysis of live animals and plants
◆ Colony Calculation
◆ Molecular weight quantification
◆ GFP expression analysis
◆ Protein quantitative analysis
◆ PCR gene expression
◆ PCR quantification
◆ TLC analysis
◆ Western blot density analysis
VisionWorksLS image acquisition and analysis software
VisionWorks LS is a mature image acquisition and analysis software that includes various tools to make capturing images of chemiluminescence, fluorescence, or colorimetric experiments (such as staining gel, colonies, spots, and membranes) simpler and faster
The functions include:
◆ Multiple image shooting methods including one click image shooting, continuous shooting, and dynamic mode shooting
◆ Image optimization, adding annotations
1D analysis, density analysis, and colony counting
◆ Multi user permission settings ensure software data security
Users can customize templates and parameter settings
◆ Generate report
◆ Expressed in accordance with FDA 21 CFR Part 11
Data reports can be directly generated into Excel spreadsheets
Application of analysis function:
◆ 1D electrophoresis gel analysis
Dot blot analysis
Analysis of live animals and plants
◆ Colony Calculation
◆ Molecular weight quantification
◆ GFP expression analysis
◆ Protein quantitative analysis
◆ PCR gene expression
◆ PCR quantification
◆ TLC analysis
◆ Western blot density analysis
◆ Multi functional darkroom with excellent light density, providing conditions for chemiluminescence imaging
◆ Zoom lens F1.2 12.5-75mm, fully automatic control of lens aperture, zoom, and focus through software
Binning function: effectively integrates pixels to improve sensitivity
Software controlled light source selection, including top reflected white light, UV 365nm, and blue light sources 460-470nm
◆ Software controlled five position filter wheel design comes standard with three filters
EtBr ethidium bromide 570-640nm
◆ SYBR Green 515-570nm wavelength
◆ SYBR Gold 485 - 655nm
◆ Equipped with an ultra-thin self luminous white screen as standard, foldable and height adjustable
◆ Drawer style UV transmission table, optional: single wavelength, dual wavelength, triple wavelength transmission table
◆ Anti UV observation window, no need to open the dark box to observe the sample situation, more intuitive and safer
VisionWorksLS professional image analysis software, capable of fully automatic control of the system
BioLite multi wavelength light source
——By connecting optical fibers, the falling light source is introduced into the dark box
BioLite is designed for live animal and plant research using the BioSpectrum and EC3 systems, and can be used simultaneously
Multi color fluorescent Western blot imaging and quantitative analysis
Biolite multi wavelength light source is a quartz halogen light source with a power of 150 watts, which is connected to an optical fiber to emit light
Light enters the dark box, providing a direct source of light for living animals and plants, as well as multi-color fluorescent Western Blots
Excitation light source Its closed optical path stably controls the output of the spectrum, thus providing better signal-to-noise ratio and
Good repeatability of the measurement results
BioLite has a 6-digit mechanical dimmer that can adjust light intensity
Equipped with 8-position filter wheels, users can choose filters with different emission wavelengths according to their experimental needs for different applications
Fluorescent dyes
The BioLite multi wavelength light source can be fully automatically controlled through the VisionWorksLS multifunctional software
Anesthesia equipment, anesthesia gas
The anesthesia equipment provides dedicated ports for easy connection of inlet and outlet anesthesia gas pipelines. Multiple ports allow for 5 samples to be made at once.
temperature control system
The temperature control platform can maintain a constant temperature in mice
Dark box - filter
|
435-575(Coomassie Blue)
|
|
465-495 (CFP)
|
|
503-523 (GFP mice)
|
|
508-582 (GFP)
|
|
513-557 (Cy2, FITC, FAM, GFP, SYBR Green, SYBR Gold)
|
|
565-625 (Alexa 555, Cy3, SYPRO Orange)
|
|
580-630 (Deep Purple, Et Bromide, RFP)
|
|
607-682 (Alexa 568, SYPRO Red, Texas Red)
|
|
700-740(IR Dye 680, CF680)
|
|
668-722 (Alexa 633, Cy5)
|
|
767-807 (Alexa 750, Cy7)
|
|
800 Long Pass(IR Dye 800, CF 770)
|
|
510-560 (SyBR Green)
|
|
520-620 (SyBR Gold)
|
BioLite Filter
|
450shortpass (CFP, SYPRO Ruby)
|
|
455-495 (Cy2, FITC, FAM, GFP, SYBR Green)
|
|
502-547 (Deep Purple, Et Bromide, RFP)
|
|
533-587 (Alexa 568, Rhodomine Red, SYPRO Red)
|
|
600-645 (Alexa 633, Cy5)
|
|
687-748 (Alexa 750, Cy7)
|
|
700-740 nm
|
|
750-780 (IRDye 800, CF 770)
|
|
uv lamp
|
|
UV light - shortwave
|
34-0007-01
|
8 Watt, 254nm
|
|
UV Lamp - Medium Wave
|
34-0042-01
|
8 Watt, 302nm
|
|
UV Lamp - Long Wave
|
34-0006-01
|
8 Watt, 365nm
|