Welcome Customer !

Membership

Help

Beijing Lijia United Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

ICAD NO2/NOx/NO analyzer

NegotiableUpdate on 02/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Patent technology for fast and accurate measurement of NO2 and NOx/NO (optional)

Product Details


ICAD NO2 / NOx / NO分析仪

picture1 ICAD 200-DSeries,19Inch rack housing,OLEDdisplay.

ICAD NO2 / NOx / NO分析仪

picture2 ICAD 200-DMSeries, compact waterproof shell, suitable forMoving in the wildernessMeasurement.

ICAD(Iterative CAvity enhanced DOASIterative cavity enhanced differential absorption spectroscopy technologyNO2/NOx/NOmeasurement systemWithin the spectral range of~430-465 nmInternally adoptedDirect optical absorption spectroscopy. By measuring absorption spectra and applying themICADAlgorithms can directly identifyNO2Unique feature absorption structure, and combines it with water vapor(H2O)Or formaldehyde(CHOCHO)Wait for other overlapping absorption to distinguish. Make it have direct measurement capabilityNO2The advantage is that it does not interfere with other substances and does not require the introduction of new interferences(For example)CLD,CRD,CAPS)The drying mechanism. due toICADThe system does not rely on absolute strength, but on characteristic differential absorption structures, thereforeThere is no absolute zero drift, and the system is insensitive to temperature changes, vibrations, and light source attenuation. Therefore, it is suitable for long-term or mobile measurement. At the same time, the system passes throughNO→NO2Internal converter based on gas-phase titration(GPT)(optional) can also be measuredNOx/NOThis instrument does not require gas consumption and is easy to operate. The data display can be directly used forWiFiperhapsLANEquipment.

Patent:EP3329251,US15/748,923.

TECHNICAL INDEX

measuring range

0-5000 ppb(Customizable)

cross sensitivity

not have

Detection limit(@30 s)

0.3 ppb

power consumption

< 30=''>,12 V (typ.)

Accuracy(1σ @30s)

0.15 ppbperhaps2%

Start Time

<1 min

NO2detection

directmeasure

temperature range

-10 – 40°C

NOx/ NOdetection

convert toNO2(GPT)

temperature sensitivity

< 0.01=''>

Response time(10%-90%)

2 s @ 1 L/minperhaps1 s @ 2L/min

weight

< 10=''>

zero drift

< 0.1=''>the moon

size

Waterproof:40×40 ×14 cm³

19Inch rack mounted:48.3×38×14 cm³

sample flow

0.5-2 L/min

Consumable gas

not have

calibration

Internal calibration, no need to calibrate gas

Other gases

H2O,CHOCHO,CO2 (optional)

Absorption pathway characterization

helium

computer system

Built in embedded systemPCData analysis and measurement software

mechanical stability

Not sensitive to vibration

data communication

LAN/WiFi/Machine2Machine/OPCUA;Bayern/Hessen (RS232);Simulate voltage/current output

application

lNO2/NOxHigh precision measurement (scientific, research, atmospheric background pollution monitoring)

lUrban air quality monitoring (outdoor, street, tunnel, canyon, mobile measurement)

lindoor air quality monitoring

lEmission monitoring (such as chimneys)

lActual driving pollutants of vehiclesEmission measurement(RDE):OptionalCO2Sensors to obtain everyKmperhapskWhofNOx/NO2

theory of operation

ICAD NO2 / NOx / NO分析仪

ICAD NO2/NOx/NOMeasurement system flowchart and measurement principle.

advantage

advantage

innovate

High measurement accuracy

•Direct measurementNO2

•High sensitivity and small measurement error

•Adaptive measurement range

•No zero or calibration drift, reproducibility100%

•No interference

•need notdryer

Cost-effective

•parallelNOMeasurement (with converter)

•Simple yet powerful settings

•No consumables (e.g. gas)

•long service life

•Quick response within seconds

Simple operation

•No gas calibration required

•High stability (insensitive to impact, vibration, and temperature)

•light weight

•Low power consumption and12Vrun

•Multiple data transmission interfaces(Machine2Machine、RS232Simulate voltage/Current)

Origin: Germany