Technical Specifications
sensitivity
Sensor type: 90 ° light scattering, 650 nm laser diode
Calibration is carried out according to ISO 12103-1 standard, using A1 to test the respiratory dust particle size range of dust, and calibration is performed using the sampling and weighing reference method
Aerosol concentration range 0.001~100 mg/m3
Particle size range 0.1~10 μ m
Minimum resolution 0.001 mg/m3
Return to zero stability with a time constant of 10 seconds and a change of ± 0.001 mg/m3 over 24 hours
The temperature coefficient is approximately+0.0005 mg/m3/℃ (the change in temperature during the last zeroing of the instrument)
traffic
User adjustable range: 0~1.8 L/min
Note: The higher range is determined by the particle size cutter and cyclone separator connected to the SidePak AM520 monitor.
temperature range
Operating range 32 ° F~120 ° F (0 ° C~50 ° C)
Storage range -4 ° F~140 ° F (-20 ° C~60 ° C)
Operating humidity 0~95% relative humidity, no condensation
Time constant (OLED display)
User adjustable range: 1 second, 5 seconds, 10 seconds, 15 seconds, and 30 seconds
Built in sampling head
Standard sampling head without specific particle size range
PM1.0 particle size cutter intercepts 50% at 1.0 μ m
PM2.5 particle size cutter intercepts 50% at 2.5 μ m
PM5.0 particle size cutter intercepts 50% at 5.0 μ m
PM10 particle size cutter intercepts 50% at 10.0 μ m
Detachable cyclone separator
4 μm Dorr-Oliver 在 4.0 μm 50% 拦截
0.8 μ m DPM intercepts 50% at 0.8 μ m
alarm
The alarm types are universal, STEL
Default settings 0.5 mg/m3, 1 mg/m3, 3 mg/m3, 5 mg/m3, 15 mg/m3, off
Range programmed through TrakPro software: 0.001~999 mg/m3
Alarm indicator: 95 decibel speaker, flashing red LED, flashing red OLED display
Second call delay of 30 seconds, 1 minute, 3 minutes, 5 minutes, 10 minutes, closed
data recording
Approximately 80000 data points (recorded every minute for 55 days)
User adjustable recording intervals: 1 second, 1 minute, 5 minutes, 15 minutes, and 30 minutes
User selectable correction factors
Factory settings 1.0 (user adjustable)
Environment setting 0.38 (user adjustable)
User defined settings 5 (using TrakPro software to customize tags)
Physical properties 0.1~10.0 (user adjustable)
physical device
Dimensions 5.1 x 3.7 x 3.1 inches 129.5 mm x 94 mm x 78.4 mm
Containing 803300 batteries
Weight 22 ounces (0.62 kg) with 803300 batteries
Display 160 x 128 resolution color OLE display
Tripod mounting nut? -20 internal threads
battery
Battery capacity 5400mAH lithium-ion battery pack
Running time at 1.7Lpm using PM2.5 cutter for over 20 hours
Charging time hours (typical situation when the battery is completely depleted)
Power supply (p/n 803302)
Input voltage range: 100~240 V AC, 50~60 Hz
Output voltage 12 V DC @ 3.0A
maintenance
Manufacturer's cleaning/calibration recommendation to be conducted annually
User zero calibration before each use
User traffic calibration based on sampling probe requirements
communication interface
Type USB 2.0
Instrument connector USB Micro-B (socket)
Minimum configuration requirements for computers using TrakPro software
Communication port Universal Serial Bus (USB) v2.0 or higher
Operating System Microsoft Windows ® 7, 8, or 10 (32-bit or 64 bit) operating systems
approve
AM520 using TSI battery pack P/N 803300
Remarks: TSI Individual Exposure Dust Analyzer, TSIAM520I, Dust Analyzer, TSI Dust Analyzer, TSIPM2.5 Dust Analyzer Detection, TSI Dust Detection Equipment, TSI HVAC Usage Detection Equipment.
TSI Individual Exposure Dust Analyzer in the United States
Model: AM520I
The TSI AM520I from the United States is a compact, portable, battery powered, and data recording light scattering laser photometer that provides real-time aerosol mass concentration readings of dust, smoke, fog, smoke, and mist in the worker's breathing area. The newly designed particle size cutting sampling head improves the performance of the equipment in measuring mass concentration and can measure different particle size cutting points for PM10, respiratory dust (PM4), PM5 (Chinese respiratory dust), PM2.5, PM1, and 0.8 μ m diesel engine emissions particulate matter (DPM). This monitor is the perfect solution for real-time individual aerosol sampling in various working environments. Related applications include general industry, foundry industry, construction sites, chemical plants, refineries, petrochemical industry, power and public facilities, transportation, aerospace, maritime, confined spaces, and mining industry.
new features
+Durable and sturdy particle size cutters can be used for higher quality concentration ranges
+Sound and light alarm
+ 0.8μm DPM 粒径切割器
+PM5 Chinese respiratory dust particle size cutter
+High capacity battery
+Color OLED display screen
Not afraid of comparison!
The user set sound and light alarm, as well as the newly designed particle size cutter with more selectable particle size ranges, make this instrument an important tool for monitoring exposure levels in work areas.
The new particle size cutter can provide reliable particle size grading and higher accuracy at higher quality concentrations and longer operating times.
Remarks: TSI am520i, TSI AM520I, TSI dust analyzer, TSI individual exposure dust analyzer, TSI particle detector, TSI dust analyzer, pm2.5 particle detector, Zhongyi Environmental Science and Technology Co., Ltd