reliable
Strengthen the concept of reliability design, adopt high-quality core components from around the world, undergo reliability verification by authoritative institutions, and ensure long-term stable operation of the system;
precise
Unique liquid delivery and sampling techniques, combined with high-sensitivity detectors and powerful data processing software, ensure precise and accurate analysis results;
friendly
Simple and user-friendlyThe Wookinglab interface, combined with multiple user-friendly detail designs, makes instrument operation more convenient and efficient;
compliance
Wookinglab adopts a database storage mode, supports multi-level permission management, and has complete audit tracking functions, fully meeting the requirements of FDA 21 CFR Part 11.
Product Introduction
K2020P2Binary high-pressure infusion pump
1The precision reciprocating plunger series infusion pump, combined with pressure dynamic suppression algorithm, makes the flow output more stable and retains the repeatability of time0.2%within
2Floating plunger design, easy to disassemble and effectively prevent seal ring from eccentric wear, combined with a specially designed seal ring structure and plunger automatic cleaning, making the seal ring more durable
3Equipped with4Channel solvent selection valve, automatically switches according to the mobile phase used in the method and sequence
4Set up a one click emptying button on the panel to quickly and automatically empty the channel,5minAutomatic rear empty stop to prevent the mobile phase from emptying
K2020ASautosampler
1、patentSampling needleDesign MatchingUltra precision injection pump ensuresExcellent injection repeatabilityHe JiLow cross contamination, more accurate analysis results
2. The unique design of the sampling robotic arm combined with motor closed-loop control and out of step protection algorithm makes the operation of the automatic sampler more stable and reliable
3Equipped with a built-in needle washing liquid degassing module, the needle washing liquid can be used without ultrasonic degassing, avoiding quantitative interference caused by bubbles
4Front end design, convenient for later maintenance and repair
K2025COcolumn oven
1Using fuzzyPIDIntelligent temperature control algorithm, dual3DAir circulation and multiple insulation layer design, temperature control accuracyUp to ± 0.1 ℃Protect peak time from external temperature interference
2、Real time leakage protection, intelligent monitoring of Peltier and cavity temperature, over temperature power-off protection, threeweightAdequate safety protection ensures the safety of both humans and machines
K2025UVDultraviolet-visible light detector
1、High throughput optical path design, reference subtraction algorithm, and ultra precision signal acquisition circuit ensure ultra-high sensitivity of the detectoru
2The patented optical path system design achieves greater than2.5AUUltra wide linearity, meeting the requirements of high concentration samplesdirectanalysisofdemand
3The design of the transmissive deuterium light path and sealed optical unit enables the detector toLong term operationMore reliable
4Equipped with pump stop scanning function, it can perform full band spectral scanning on compounds, easily finding the optimal absorption wavelength of the compound
5Equipped with wavelength time program function, it can switch between different wavelengths to analyze different compounds at different time periods in the method, improving analysis efficiency and result accuracy
Wookinglabworkstation
1The points module has25Points based events and3Develop quantitative calculation methods to better complete data processing of various complex spectra
2The workstation adopts a database storage mode with complete permission grading and design tracking functions,Fully satisfiedFDA 21 CFR Part 11Compliance requirements
3The workstation has built-in standard methods that can be directly retrieved and called