Welcome Customer !

Membership

Help

Shanghai Xuansheng Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Shanghai Xuansheng Scientific Instrument Co., Ltd

  • E-mail

  • Phone

    15021595718,15121127657

  • Address

    Jiading Industrial Park, Shanghai

Contact Now

LNG Quality Report Testing Instrument Natural Gas Analyzer

NegotiableUpdate on 04/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
LNG temperament report detection instrument, natural gas analyzer, portable gas chromatograph
Product Details

LNG Quality Report Testing Instrument Natural Gas AnalyzerPortable gas chromatograph

So far, the effective method for analyzing gas composition is to useGas ChromatographyGas chromatography is a physical and chemical separation and analysis method. When analyzing the composition of gas, we send the measured gas sample into the injection port of the gas chromatograph through the quantitative tube of the chromatograph. The various components in the gas sample are gradually separated by the carrier gas after passing through the injection port, and then enter the detector. The detector converts the concentration signals of each component that flows out in a certain order after passing through the chromatographic column into electrical signals. After detection by the measuring arm, a spectrum peak area chart arranged in chronological order is formed. These chromatograms can be qualitatively analyzed and quantitatively calculated by microcomputer software to obtain the percentage content of each component in the analyzed gas sample. Therefore, in gas chromatography, the chromatographic column and detector are two key components

Model comparison:

Instrument model

Applicable fields

Testing components

Test results

GC-8850

LNG

Nitrogen, methane, ethane, propane

Component content, high calorific value, low calorific value, density, relative density, and white matter number.

GC-9850

LNG、CNG、 Pipeline gas

Nitrogen, methane, ethane, propane, n-butane, isobutane

Economic intelligent natural gas analyzer portable gas chromatograph

The box type design is easy to carry and move. The instrument has a stylish appearance and beautiful appearance; 8-inch display screen, displaying rich and intuitive content; Small in size, light in weight, and easy to carry, it is suitable for laboratory testing and analysis of LNG users, as well as for gas companies to carry instruments to multiple user points for testing.

Natural gas analysis is mainly used for natural gas production manufacturers and liquid plant testing equipment. The third-party testing standard is based on the unified analysis results of the Shanghai Xuansheng Natural Gas Analyzer testing execution standard, and the self injection method eliminates errors caused by manual injection to achieve precise and accurate reproducibility of analysis results

LNG Quality Report Testing Instrument Natural Gas AnalyzerPortable gas chromatographProduct Description: How to Translate

GC-The 8850 fully automatic gas analyzer is a high-performance instrument produced by Shanghai Xuansheng Scientific Instrument Co., Ltd. It is mainly used for detecting liquid nitrogen in LNG, detecting methane, ethane, and propane content, analyzing natural gas calorific value and density, and calculating gasification rate based on density.

Natural gas analysis manufacturer Shanghai Xuansheng Kexueyiq Youxian Company's main product is natural gas company, gas equipment manufacturer, natural gas vaporizer user, LNG transportation manufacturer * product

Natural gas blending analysis, natural gas calorific value analysis, natural gas gasification rate analyzer

The operation of this instrument is very simple, even personnel who have not been in contact with this instrument can learn it at once. Insert the gas sampling bag into the 'sample inlet' of the instrument, and press the 'start' button to automatically run the instrument (automatic sampling, automatic analysis, automatic signal collection, no need for manual intervention). Automatically calculate the detection results within 10 minutes.

This machine integrates an analysis column, detector, working software, and computer. Convenient to carry, suitable for both online pipeline inspection in industrial sites and airbag sampling analysis in laboratories;

● Integrated sealed heating, with low heat dissipation ratio, higher efficiency, and energy savings;

● Dual channel calorific value working software, automatically calculates the detected gas component content, high calorific value, low calorific value, density, relative density, Huabai number, combustion potential, etc;

Built in automatic sampling pump and electric injection valve to improve the repeatability of detection results;

Can be equipped with a mouse and printer;

Reference standards:
GB/T 10410-2008 "Gas Chromatography Analysis Method for Constant Components of Artificial Gas and Liquefied Petroleum Gas"
GB/T 12208-2008 "Determination of Composition and Impurity Content of Artificial Gas"
GB/T 11062-1998 "Calculation Method for Heating Value, Density, Average Density, and Wopo Index of Natural Gas"
SH/T 0230-92 "Determination of Composition of Liquefied Petroleum Gas (Chromatography Method)"
GB/T 13610-2003 "Composition Analysis of Natural Gas - Gas Chromatography Method"
GB/T 12206-2006 "Determination of Heating Value and Relative Density of Urban Gas"
GB 10410.1-89 "Gas Chromatography Analysis Method for Components of Artificial Gas"
GB 10410.2-89 "Gas chromatographic analysis of constant components in natural gas"
GB 10410.3-89 "Gas Chromatography Analysis of Liquefied Petroleum Gas Components"

Product advantages

Convenient to carry

Portable gas analyzer Portable automatic gas analyzer

This instrument adopts a modular design, with one click start, making operation easier and reducing costs

Technical requirements for personnel include automatic sample extraction, automatic sample injection, and automatic data collection,

Automatically calculate results.Carrier gas: high-purity hydrogen gas (purity ≥ 99.995%)

Built in calorific value software automatically calculates component content, high calorific value, low calorific value, density, relative density, Hua Bai number, and combustion potential

TCD sensitivity S ≥ 3000mv. ml/mg (benzene) noise ≤ 0.02mv

Air intake requirements: dust-free, waterless, oil-free

Built in injection valve: automatic injection, automatic reset (module control)

Qualitative time error: ≤ 0.02min

Detection *. 1%