E-mail
grgtest@grgtest.com
- Phone
-
Address
No. 163, Xipingyun Road, Huangpu Avenue, Tianhe District, Guangzhou City
Guangzhou Radio and Television Metrology Testing Co., Ltd
grgtest@grgtest.com
No. 163, Xipingyun Road, Huangpu Avenue, Tianhe District, Guangzhou City
In the field of lightning protection testing, Radio and Television Metrology has obtained the Level B qualification certificate for lightning protection device testing issued by the meteorological department, the CMA qualification certification for inspection and testing institutions, and the CNAS laboratory accreditation certificate from the China National Accreditation Service for Conformity Assessment, which can provide professional technical services to customers.
Radio and television metrology has established corresponding lightning protection detection service capabilities based on relevant standards, which can solve lightning safety problems for customers and eliminate safety hazards caused by lightning safety issues.
Applicable product scope:
Lightning protection detection, lightning protection device detection, anti-static grounding detection, soil resistivity detection, grounding resistance detection, earth network detection, equipotential detection, closed loop detection, surge protection device (SPD), electromagnetic shielding detection, technical review of lightning protection design drawings, etc.
5-7 business days
GB 50057-2010、GB/T 21431-2015、DB11/ 634-2018 5.4、QX/T 186-2013、YD/T1429-2006、GB/T 33676-2017、DL/T 475-2017TheDB44T1797-2016、GB/T19271.3-2005/IEC TS 61312-3:2000
| Testing Standard | Test Project |
| Design Code for Lightning Protection of Buildings GB 50057-2010 |
1. Lightning arrester: grounding resistance, transition resistance, closed loop resistance, bracket tension, grid specification and size inspection, height, length, specification and size inspection 2. Downlead: Grounding resistance, transition resistance, closed loop resistance, spacing, specifications, and size inspection 3. Grounding device: inspection of grounding resistance, grounding body specifications and dimensions 4. Equipotential connection: inspection of transition resistance, specifications, and dimensions 5. Surge protection device: protection grounding inspection, performance parameter and installation process inspection, overcurrent protector inspection, transition resistance, voltage sensitive test, leakage current test, insulation resistance test 6. Electromagnetic shielding: inspection of transition resistance, shielding material specifications and dimensions 7. Soil resistivity: Soil resistivity change test, soil vertical and horizontal stratification change test 8. Grounding resistance of the earth network: testing of the power frequency characteristic parameters of the grounding device |
| Technical Specification for Testing Lightning Protection Devices in Buildings GB/T 21431-2015 |
|
| Technical Specification for Testing Lightning Protection Devices of Building Electronic Systems DB11/ 634-2018 5.4 |
|
| Lightning protection requirements and detection technical specifications for security prevention systems QX/T 186-2013 |
|
| Technical requirements and methods for defense systems in use by communication bureaus (stations) YD/T1429-2006 |
|
| Technical Specification for Lightning Protection Device Testing of Communication Bureaus (Stations) GB/T 33676-2017 |
|
| Guidelines for measuring characteristic parameters of grounding devices DL/T 475-2017 |
|
| General Requirements for Lightning Protection Device Testing Service DB44T1797-2016 | |
| Protection against lightning electromagnetic pulses - Part 3: Requirements for surge protectors GB/T19271.3-2005/IEC TS 61312-3:2000 |